Skip to main content

Posts

Showing posts from November, 2019

Chongqing Cummins Technical Center Started Operation

Recently, Chongqing Cummins Technical Center officially started operation in Liangjiang New Area. According to sources, the center is Cummins’ first research and development center for developing large horsepower engines in China. Its operation will greatly boost the Cummins competitiveness in developing large horsepower diesel engines and natural gas engines. With 50-50 shares from Chongqing Machinery and Electronics Holding (Group) Co., Ltd. and Cummins, Chongqing Cummins has been in business for 24 years and has become the most well-known production base of large horsepower engines. Currently, its products are well received both at home and abroad. The first phase of the technical center boasts six engine trial operation rooms, which are able to test the performances, emissions and reliability of 14L-72L engines. In the near future, the center is capable of providing US Tier 4 Final test, Euro non-road Stage IV test, China non-road IV test. “Chongqing Cummi...

25 KVA - 3000 KVA Standby Diesel Generator Factory Assembly Line

Starlight diesel generator/DG set/genset factory assembly line - 20 kva - 3000 kva. 50/60Hz, 380/400/415V, 3 phase 4 wire generator. Cummins generator: 25 kva to 1875kva (DCEC & CCEC) Volvo generator: 85 kva - 750 kva (Volvo Penta) Perkins generator: 30 kva - 2250 kva (USA, India) Yuchai generator: 25 kva - 3000 kva SDEC generator: 62.5 kva - 1000 kva MTU generator: 1750 kva - 3125 kva (Yuchai - MTU) Starlight standby diesel generator models

Faults and Elimination Methods for Emergency Diesel Generator

Emergency Diesel Generator Faults Fault Fault characteristics and causes Elimination method Oil pressure alarm shutdown Pressure sensor broken Replace the pressure sensor Poor quality of lubricating oil Replace the lubricating oil Oil filter is dirty Replace the oil filter Pressure valve failure Repair or replace pressure valves Oil pump failure Replace the oil pump Insufficient oil Add oil High water temperature alarm and stop Insufficient cooling water Add cooling water, the cooling water must be distilled water Engine cannot start Water temperature sensor is broken Replace the water temperature sensor Tubing has air Check, exhaust air Tank valve is not open Open the oil tank valve Oil tank without oil Add fuel Poor fuel quality Replace the fuel Starter motor failure Replace the starting motor Insufficient battery capacity Charge the battery Battery terminal oxidation, poor contact Rust remov...

CCEC Cummins Power Generation Engine

CCEC Cummins engine used in diesel generator set . Power range is from 200KW to 1500KW. All the engines are new engines. CCEC Cummins engine features with high power, low emission, stable performance and low noise, etc.

How to Operate Emergency Diesel Generator?

As a backup power source, emergency diesel generator provides AC power to the load in case of main power failure, ensuring continuous power supply of the load. It is widely used in various industries such as communication, coal mine, etc., and various faults occurred in the operation of the diesel generator set. Most of them are caused by untimely, inoperative or improper operation of the operation manager. Emergency Diesel Generator Start-up Operation Release the "emergency stop" button on the control panel. Turn the power switch knob on the control panel to the “ON” position, the power indicator light is red, and the generator's controller power is on and displays normally. Press the manual button on the generator controller panel, the indicator on the manual button lights up, and a palm is displayed in the lower right corner of the LCD screen. This is the manual start mode. Press the start button on the generator controller panel to start ...

How to Maintain 500KW Volvo Diesel Generator Set

1.Primary technical maintenance: 50-80 hours. (Added to the content of daily maintenance) A. Replace and clean air filter if necessary. The air filter is an unconspicuous but important part of the whole diesel generator set. Once the air filter is too dirty, it may cause serious mechanical accidents, especially in the environment and areas with poor air quality. In order to avoid shortening the service life of diesel generator , after shutdown, check the air filter in time and whether the air filter is blockage and damage. If so, clean and replace it in time. B. Check and replace the fuel filter and water filter; C. Check the tension of the drive belt; D. Add lubricating oil to all oil injection nozzles and lubricating parts; E. Replace cooling water. 2.Secondary technical maintenance: 250-300 hours. (Added to the contents of daily maintenance and primary maintenance) A. Clean the piston, piston pin, cylinder sleeve, piston ring and connecting rod bearing...

800KW Heavy Duty Emergency Diesel Generator Set Powered by Yuchai Engine

New 800KW 1000KVA Yuchai Diesel Generator Set -  Blue Colour Model: XG-800GF Rated current: 1440A Rated frequency: 50Hz Rated speed: 1500rpm Power factor: 0.8 lagging Rated voltage: 400V Engine: Yuchai / YC6C1320-D31 Alternator: Starlight / TFW2-800-4A Controller: SmartGen / 6110 Email: sales@dieselgeneratortech.com

How to Operate Perkins Generator in Winter?

To operate Perkins generator smoothly in winter, some things need to be noted. For example, a low temperature start method, a choice of lubricating oil, a need for a water jacket heater, and the like. Please refer to the following information for details. The low fuel temperature in winter makes the viscosity of diesel oil increase and the fluidity deteriorates, which causes the diesel to be difficult to spray, resulting in poor atomization and even deterioration of combustion, which makes the diesel engine's power and economic performance decline. Therefore, light diesel oil with low freezing point and good ignition performance should be selected in winter. It is generally required that the freezing point of diesel engine should be lower than the local current season temperature 7 - 10°C. Use an open flame to start the machine   where the temperature is too low, but do not remove the air filter. After the cotton yarn is ignited on the diesel oil, the igniter is pl...

Cummins Emergency Diesel Generator - Starlight Power

Starlight Power manufactures 25kva to 3000kva Cummins emergency diesel generator set 50Hz/60Hz, 1500rpm/1800rpm water cooling industrial generators with good quality. DCEC Cummins generator for 25kva to 500kva. CCEC Cummins generator for 250kva to 1870kva. Import Cummins for 25kva to 3000kva. Standard generator configuration: industrial silencer, air filter, fuel filter, oil filter, battery, shock pad, maintenance tools for CCEC Cummins, fuel tank, 50°C radiator etc.

Emergency Diesel Generator Moisture-proof Measures

We can install generator damp proof heater and control panel moisture-proof heater on emergency diesel generator to resolve moisture problem. Because generator damp proof heater and and control panel moisture-proof heater is optional part, when users purchase, should tell the supplier. The attention on moisture-proof for diesel generator set: 1.Heating and drying shall be carried out in clean air, and the generator shall be blown clean with compressed air before drying. If the winding is seriously wet, it needs to be dried by hot air method first. After drying, dry with load to avoid insulation breakdown. When drying, we should put more thermometers in the parts of industrial diesel genset, so as to grasp the temperature of each part and reduce local overheating. Heating shall be carried out slowly to avoid insulation damage caused by sudden evaporation of moisture in the coil. 2.If the drying temperature does not reach the required temperature, it can be dried at a sli...

Advantages of Starlight Container Silent Diesel Generator

Characteristic of Starlight container silent diesel generator 1.Install with standard 20 feet or 40 feet container which is retrofitted, this can make the unit more flexible and convenient. 2.Including all functions of the standard silent type diesel generator set. 3.Laying sound absorbing cotton and metal perforated board inside the container box. 4.Equipped with industrial muffler, which has compact structure and good noise elimination effect. 5.Equipped with fuel supply system, control room, lighting system, cooling system, and maintenance space is reserved. 6.With high corrosion resistance, and all screws and bolts are rust proof. Advantages of Starlight container silent diesel generator 1.According to the world standard container planning and manufacturing, 20 feet for less than 1000KVA and 40 feet for more than 1250kva. 2.With CSC certificate of world container safety convention, the whole set can be directly shipped as a standard container, greatly s...

Methods to Prevent Diesel Generator Set from Burning Down

Keep diesel generator set clean. During the operation of the generating unit, if dust, water stains and other debris enter the interior, a short-circuit medium will be formed, which will damage the insulation layer of the wire, causing a short circuit between turns, and the temperature will rise to burn down the diesel genset. Therefore, dust, water stains and other sundries should be prevented from entering the generator set , and the outside of the diesel generator set should be cleaned frequently to ensure good heat dissipation of the genset. Observe the diesel generator set for vibration, noise and abnormal odor. In the operation of diesel generator sets, especially high-power gen sets, it is necessary to check whether the anchor bolts, the end cover of the generating set, and bearing glands are loose, and whether the grounding device is reliable. If it is found that the vibration of the diesel generator set is intensified, the noise is increased and the odor is genera...