Skip to main content

Advantages of Starlight Container Silent Diesel Generator


Characteristic of Starlight container silent diesel generator

1.Install with standard 20 feet or 40 feet container which is retrofitted, this can make the unit more flexible and convenient.
2.Including all functions of the standard silent type diesel generator set.
3.Laying sound absorbing cotton and metal perforated board inside the container box.
4.Equipped with industrial muffler, which has compact structure and good noise elimination effect.
5.Equipped with fuel supply system, control room, lighting system, cooling system, and maintenance space is reserved.
6.With high corrosion resistance, and all screws and bolts are rust proof.


1.According to the world standard container planning and manufacturing, 20 feet for less than 1000KVA and 40 feet for more than 1250kva.

2.With CSC certificate of world container safety convention, the whole set can be directly shipped as a standard container, greatly saving the transportation cost.

3.For the convenience of user operation and maintenance, we equip with 2 explosion proof lamps in the container, and an explosion-proof lamp on the control panel.

4.The front and back of the container can be opened, and both sides of the container are equipped with side doors, which is convenient for users to maintain and repair.

5.All hinges, locks and bolts are made of stainless steel. Anti wave and anti rain corrosion devices are installed in the container.

6.The control panel and output switchgear are on the same side of the container for daily operation and output cable connection.

7.Standard configuration with permanent excitation PMG system to improve the motor starting ability and the waveform distortion with immunity.

8.Fuel tanks and pipelines, oil emissions, muffler, and so which are many unique design. Many users are of all ages.

9.Silent container genset is equipped with flame retardant sound insulation and sound absorption materials with high performance and aging resistant. Excellent design of air inlet and exhaust to reduce noise.

10.The noise reduction effect is 70-80dba (Lp7m).



The whole frame structure of container silent generator room, modular planning, production and installation, and equipped with air inlet and exhaust silencing room and exhaust noise silencing system, rainproof, dustproof, noise reduction, heat preservation, sound absorption, high temperature resistant materials and perfect air flow curve planning for ensuring smooth air inlet and exhaust, temperature control and noise reduction, modular installation.

Standard features of container silent diesel generator

Radiator 50℃ max
Fans are driven by belt, with safety guard
24V charge alternator
Dry type air filter, fuel filter, oil filter
Alternator: single bearing alternator
IP23, insulation class H/H
Main line circuit breaker
Standard control panel
Absorber
Muffler
Optional parts include: automatic fuel adding pump (or control valve) / coolant adding pump / dual oil-water separator / automatic parallel system, etc.

Starlight container silent diesel generators are suitable for construction in places with strict requirements on noise pollution, such as hospitals, offices, outdoors and field fixed places, and also improves the ability of the unit to prevent rain, snow and sand.

Starlight series container silent diesel generator set covers Cummins, Volvo, Perkins, Deutz, Yuchai, Shangchai, Ricardo, Weichai etc. You can choose any one of them according to your requirement. Contact us by email sales@dieselgeneratortech.com or call us +86 134 8102 4441.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Choose a Household Mini Generator

With the improvement of people's living standards, there are more and more household appliances, such as rice cookers, microwaves, kettles, refrigerators, air - conditioners, washing machines, etc. It can be said that every household has them. But what if there is a power outage? These appliances won't work properly, and our lives will be greatly disrupted. How can we avoid this? We can use household mini - generators to provide convenience in power consumption. So, how to choose a good household mini - generator? Consider the noise level Since it is for household use, when choosing a household mini - generator, we need to check whether the noise will affect the neighbors. Generally, the seller will demonstrate the performance of the generator in advance. A good household generator can reduce noise by about 80%. Choose a generator with a moderate price Due to different brands, there are significant differences in power, and consequently, the price differences of househ...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...