Advantages of Starlight Container Silent Diesel Generator


Characteristic of Starlight container silent diesel generator

1.Install with standard 20 feet or 40 feet container which is retrofitted, this can make the unit more flexible and convenient.
2.Including all functions of the standard silent type diesel generator set.
3.Laying sound absorbing cotton and metal perforated board inside the container box.
4.Equipped with industrial muffler, which has compact structure and good noise elimination effect.
5.Equipped with fuel supply system, control room, lighting system, cooling system, and maintenance space is reserved.
6.With high corrosion resistance, and all screws and bolts are rust proof.


1.According to the world standard container planning and manufacturing, 20 feet for less than 1000KVA and 40 feet for more than 1250kva.

2.With CSC certificate of world container safety convention, the whole set can be directly shipped as a standard container, greatly saving the transportation cost.

3.For the convenience of user operation and maintenance, we equip with 2 explosion proof lamps in the container, and an explosion-proof lamp on the control panel.

4.The front and back of the container can be opened, and both sides of the container are equipped with side doors, which is convenient for users to maintain and repair.

5.All hinges, locks and bolts are made of stainless steel. Anti wave and anti rain corrosion devices are installed in the container.

6.The control panel and output switchgear are on the same side of the container for daily operation and output cable connection.

7.Standard configuration with permanent excitation PMG system to improve the motor starting ability and the waveform distortion with immunity.

8.Fuel tanks and pipelines, oil emissions, muffler, and so which are many unique design. Many users are of all ages.

9.Silent container genset is equipped with flame retardant sound insulation and sound absorption materials with high performance and aging resistant. Excellent design of air inlet and exhaust to reduce noise.

10.The noise reduction effect is 70-80dba (Lp7m).



The whole frame structure of container silent generator room, modular planning, production and installation, and equipped with air inlet and exhaust silencing room and exhaust noise silencing system, rainproof, dustproof, noise reduction, heat preservation, sound absorption, high temperature resistant materials and perfect air flow curve planning for ensuring smooth air inlet and exhaust, temperature control and noise reduction, modular installation.

Standard features of container silent diesel generator

Radiator 50 max
Fans are driven by belt, with safety guard
24V charge alternator
Dry type air filter, fuel filter, oil filter
Alternator: single bearing alternator
IP23, insulation class H/H
Main line circuit breaker
Standard control panel
Absorber
Muffler
Optional parts include: automatic fuel adding pump (or control valve) / coolant adding pump / dual oil-water separator / automatic parallel system, etc.

Starlight container silent diesel generators are suitable for construction in places with strict requirements on noise pollution, such as hospitals, offices, outdoors and field fixed places, and also improves the ability of the unit to prevent rain, snow and sand.

Starlight series container silent diesel generator set covers Cummins, Volvo, Perkins, Deutz, Yuchai, Shangchai, Ricardo, Weichai etc. You can choose any one of them according to your requirement. Contact us by email sales@dieselgeneratortech.com or call us +86 134 8102 4441.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...