Skip to main content

Posts

Showing posts with the label Perkins generator

How to Maintain Perkins Generator Set by Wrenches?

Do you know how to maintain Perkins generator set by wrenches? There are four kinds of wrenches in common use: open wrench, ring wrench, adjustable wrench and socket wrench.   1.Open wrench.   Open wrenches are often used on bolts with narrow mechanical range of motion. Because its handle and head keep a certain angle (15 ° ~ 45 °), which increasing the distance of machining activity. Therefore, the turning speed can be increased, and the contact with the nut is also convenient. It can be sleeved up and down or inserted directly.   The commonly used open wrench is double end open. Its specification is indicated by the opening of the head. Wrench with different opening width is used for turning hexagon nuts or bolts of different specifications. The specifications of commonly used open-end wrenches (mm × mm) are 6 x 7, 8 x 10, 9 x 11, 10 x 12, 11 x 13, 12 x 14, 13 x 15, 14 x 17, 17 x 19, 19 x 22, 22 x 24, 24 x 27, 27 x 30 and 30 x 32, etc. 2.Double offset rin...

How to Operate Perkins Generator in Winter?

To operate Perkins generator smoothly in winter, some things need to be noted. For example, a low temperature start method, a choice of lubricating oil, a need for a water jacket heater, and the like. Please refer to the following information for details. The low fuel temperature in winter makes the viscosity of diesel oil increase and the fluidity deteriorates, which causes the diesel to be difficult to spray, resulting in poor atomization and even deterioration of combustion, which makes the diesel engine's power and economic performance decline. Therefore, light diesel oil with low freezing point and good ignition performance should be selected in winter. It is generally required that the freezing point of diesel engine should be lower than the local current season temperature 7 - 10°C. Use an open flame to start the machine   where the temperature is too low, but do not remove the air filter. After the cotton yarn is ignited on the diesel oil, the igniter is pl...

How to Judge the Abnormal Sound of Perkins Generrator

When Perkins diesel generator is operating, the noise is mainly from mechanical friction sound of diesel engine. Experienced technicians can judge the hidden trouble of a part of diesel engine from the sound. We can judge fault from following sound: 1.When Perkins diesel engine is running at low speed (idle speed), the metal knocking sound of "bar da, bar da" can be heard beside the valve cover. This sound is caused by the impact between the valve and the rocker arm. The main reason is that the valve clearance is too large. Valve clearance is one of the main technical indexes of diesel engine. If the valve clearance is too large or too small, the diesel engine will not work normally. Too large valve clearance causes the displacement between the rocker arm and the valve to be too large, and the impact force generated by the contact is also large, so we can hear the metal knocking sound of "bar da, bar da". This kind of sound often appears after the engine...

Perkins 2506C-E15TAG2 Diesel Generator Introduction

Perkins 2506C-E15TAG2 is a turbocharged and air-to-air chargecooled, 6 cylinder diesel engine. Its premium features provide economic and durable standby duty, exceptional power-to-weight ratio resulting in exceptional fuel consumption and low gaseous emissions and advanced overall performance and reliability making this the prime choice for today’s power generation industry. Economic Power Mechanically operated unit fuel injectors with advanced electronic control, combined with carefully matched turbocharging, give excellent fuel atomisation which leads to exceptional low fuel consumption. Reliable Power Developed and tested using the latest engineering techniques and finite element analysis for high reliability. Low oil usage and low wear rates. High compression ratio ensures clean rapid starting in all conditions. Support comes from a worldwide network of 4,000 distributors and dealers. Compact, Clean and Efficient Power Exceptional power to weight rat...

Main Blockages in Perkins Diesel Generator

To judge whether there are three blockages in Perkins diesel generator , the inspection method is to remove all high-pressure fuel pipes from the injection pump. One person plays the starter to drive the diesel engine and the injection pump to run. One person observes the oil discharge situation at the outlet valve of the high-pressure pump, and can easily distinguish the three kinds of blockage situation. 1.If the diesel engine can supply oil normally, while before disassembly, diesel engine operates unstable, it can be judged as water blockage, the main reason is that too much water in diesel oil, so that makes the engine unstable or unable to work. 2.If a lot of bubbles come out, while before disassembly, Perkins diesel engine can not work or unstable work, it can be judged as air blockage, the main reason is that there is air in diesel engine, so that diesel engine can not work. 3.If there is not oil supply, or supply little oil, it can be judged as foreign bod...

Main Features of Perkins Generators

Perkins is a British based company that is one of the top diesel generator manufacturing companies in the world. With parts and service centres located worldwide. Perkins Generators (engines) was founded in 1932, offering diesel and natural gas as their base fuels for their engines.   They are very popular in the market due to their economy, reliability, and durability. The majority of Perkins Generators uses diesel engines to drive the generator thus converting the diesel energy into electrical energy or power. Perkins Generators are suitable for commercial, construction, industrial, agricultural and residential power generation and there is sure to be a Perkins Generator to suit your needs. Perkins Generators are known for providing high-quality generators with a lot of efficiency and reliability. Main Features of Perkins Generators: An engine driving cooling fan with protection guard. Fuel lubricating oil and air filter with restriction indicat...

Fuel Consumption of 400KVA Perkins Generator

400 kva Perkins diesel generator is 3 phase 4 wire 50 Hz & 1500 rpm or 60 Hz & 1800 rpm? The model is 2206C-E13TAG2 or 2206C-E13TAG3? It is standby generator, the fuel consumption is given below: The 2200 range has been developed using the latest engineering techniques and builds on the strengths of the already very successful 2000 Series family. Developed from a proven heavy-duty industrial base, these products offer the superior performance and reliability required to meet today’s uncompromising demands within the power generation industry. The 2206C-E13TAG3 is a 6 cylinder, turbocharged air-to-air charge cooled diesel engine. Its premium features provide exceptional power to weight ratio resulting in exceptional fuel consumption. The overall performance and reliability characteristics make this the prime choice for today’s power generation industry. Starlight Perkins series diesel generator units apply diesel engines from Perkins Engines Co., ...

How to Maintain Perkins Engine Diesel Generator

What are the preparations for the Perkins generator before starting 1. Open the supply valve and return line (if equipped). 2. If the engine does not start for several weeks, the fuel may escape from the fuel system and some bubbles may be trapped in the engine fuel system when the fuel filter is replaced. In these cases, the oil should be pumped manually to the fuel system. 3. Ensure that two air cutoff valves 1 (shown below) are in open position. 4. If the engine does not start for more than 3 months, the engine oil system must be pumped manually. Follow these steps to pump the engine oil system. A. Disconnect the speed sensor connector on the governor control and make sure the governor stops in the stop position. B. Switch the key to the starting position. Keep the key switch in this position until the oil pressure gauge indicates 100kpa (14.5040psi). Keep the key switch in the starting position for 10 seconds. Note: the key switch is part of the panel ...

ELC Cooling System Maintenance - Perkins Diesel Generator

I Long-lasting coolant addition Use premixed or concentrated coolant only for Perkins products. Perkins extenders can only be used with long-life coolants. Mix long-life coolant with other products to reduce the life of long-life coolant. The failure to do so will reduce the life of the cooling system components unless proper remedial action is taken. Perkins Low Noise Diesel Generator Set To maintain the correct balance between coolant and additives, the recommended concentration of long-life coolant (ELC) must be maintained. Lowering the proportion of the coolant also reduces the proportion of the additive. This will reduce the ability of the coolant protection system to resist pitting, cavitation, erosion and deposits. Note: Be careful not to use conventional coolant to supplement the cooling system filled with long-life coolant (ELC). do not use the standard supplemental coolant additive (SCA). The ELC extender is only used in the RLC cooling system. Do not us...

Perkins Generator Fails to Function Properly

Perkins 2500 series Generator  has a diesel-powered engine and a Leroy Somer alternator . This high-quality generator has several alarm and shutdown protection features built into the machine.  Shutdown Perkins generators shut down automatically for any of the following reasons: generator over-volts or under-volts, over or under speed, over or under frequency Hz and low or high oil pressure. When the generator shuts down you will see a flashing red light. Alarm An alarm will sound if the Perkins generator fails to function properly for the following reasons: high current, battery charge failure, high and low battery volts, failure to rest or a loss of speed sensing signal. An auditory alarm will sound and an amber LED light will light up but not flash. Digital Control System A set mounted digital control system provides metering and LED light indicators for shutdown and alarm functions. This panel will display readings for the components responsible for an alarm or shutdown so...