Check connection bolt Check the bolts for Deutz diesel engine, generator , injector and intake/exhaust manifold and the connection of bolts and hoses, re tighten them if necessary. Tighten cylinder head bolts Loosen the cylinder head bolts about 1/4 of a rotation when engine warming, and then tighten them up with a force of 200+ 10 Nm immediately according to the sequence as the following figure. Check and tension the V-belt Press the V-belt with hand, the distortion should not be more than 10-15mm, otherwise change the belt with a new one. If tension the belt through generator, loose bolt 1 and bolt 2 firstly, stain the generator outwards, then tighten up bolt 1 and bolt 2 and check the belt by hand. If tension the belt through tension pulley, loose the bolt 3 and bolt 4 on bracket 5, stain the tension pulley bracket, and then tighten up bolt 3 and 4 and then check the belt by hand. Caution: Change the damage or oiled belt. Ch...
This blog mainly shares technical problems and solution of diesel generator set