Methods to Prevent Diesel Generator Set from Burning Down


Keep diesel generator set clean. During the operation of the generating unit, if dust, water stains and other debris enter the interior, a short-circuit medium will be formed, which will damage the insulation layer of the wire, causing a short circuit between turns, and the temperature will rise to burn down the diesel genset. Therefore, dust, water stains and other sundries should be prevented from entering the generator set, and the outside of the diesel generator set should be cleaned frequently to ensure good heat dissipation of the genset.



Observe the diesel generator set for vibration, noise and abnormal odor. In the operation of diesel generator sets, especially high-power gen sets, it is necessary to check whether the anchor bolts, the end cover of the generating set, and bearing glands are loose, and whether the grounding device is reliable. If it is found that the vibration of the diesel generator set is intensified, the noise is increased and the odor is generated, it is necessary to stop as soon as possible to find out the cause and eliminate the fault.

Keep the working current of the diesel genset in a stable state. Due to excessive load, low voltage or mechanical jam of the generator set will cause overload operation of the diesel power generating set. Therefore, in the operation of the generator, it is necessary to pay attention to checking whether the transmission is flexible and reliable, whether the concentricity of the coupling is standard, the flexibility of the gear transmission, etc. If any stuck phenomenon is found, it is necessary to stop the machine immediately and eliminate the fault before running.

Regularly inspect and repair the control equipment of the diesel generator set to ensure its normal operation. The technical status of the diesel generating unit control equipment plays a decisive role in the normal start of the generator set. Therefore, the control equipment of the power generating set should be located in a dry, ventilated and easy to operate position, and regularly dust. Frequently check whether the contactor contacts, coil core, wiring screws, etc. are reliable, and the mechanical parts are flexible, so as to maintain a good technical state, thus ensuring that the diesel genset works smoothly without being burned.

Always check whether the temperature and temperature rise of the power generator set are too high in operation. It is necessary to check whether the bearing of the diesel generator set is overheating and lack of oil. If the temperature rise near the bearing is found to be too high, it should be stopped immediately for inspection. Whether there is crack, scratch or damage on the rolling body and the raceway surface of the bearing, whether the bearing clearance is excessively shaken, and whether the inner ring rotates on the shaft and so on. If the above phenomenon occurs, the bearing must be renewed.

Check whether the three-phase current of the diesel generator set is balanced. For three-phase asynchronous diesel generator sets, the difference between the average value of any one-phase current and the other two-phase current shall not exceed 10%, so as to ensure the safe operation of the generator set. If it exceeds, it indicates that the genset is faulty. It should find out the cause and eliminate the fault before running.

Note that the above operation can not only improve the performance of the generating set, but also extend the life of the unit. Starlight is a professional manufacturer of diesel generator sets, which can produce various types of generator sets according to customer needs. Brands include Cummins, Perkins, Volvo, Deutz, Ricardo, Shangchai, Weichai and Yuchai.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...