Skip to main content

Posts

Showing posts with the label Starlight Power

Maintenance Contributes to Stable Operation of Diesel Generator Sets

 I believe that all users know that diesel generators, like all mechanical equipment, require regular maintenance. Proper maintenance will help improve the safe and stable operation of diesel generator sets. As a leader in the diesel generator industry, Jiangsu Starlight Electricity Equipments Co.,Ltd. will introduce to you how to properly maintain the diesel generator set. 1. Check for fuel delivery problems. Inspection of fuel delivery is an important generator set maintenance technique. It will ultimately help you increase the productivity of your generator set. There is a carburetor inside the genset engine. The main purpose of the carburetor is to mix the gasoline in the tank with air. This must be sufficient for ignition to occur in the engine. If it fails when starting the generator, you can say that your generator set has a fuel delivery problem. It must be ensured that the carburetor has the proper fuel needed to start the equipment. Eliminating the air filte...

Starlight Power Signed Contract of 375kva Silent Cummins Genset

On June, 2020, Mr.Nour Fawaz from UAE contacted us by email for inquiry 300KW diesel generator, this is a tender in Ethiopia. They participated in the bidding on behalf of us.  Although this is the first cooperation with Mr.Nour Fawaz and his team, and the opening time is a little long, but we are informed that we won the bid on october, 2020. This is the result of our joint efforts and cooperation with our customers.  Thanks for your cooperation, Mr.Nour Fawaz and your team.   This 300KW diesel generator set is used for a project in Ethiopia, Starlight Power company finished production in only 15 days. After everything qualified, we delivered to the purchaser in Ethiopia.    Starlight 300KW Cummins Silent Diesel Generator Exported to Ethiopia 1.Main technical specifications of 300KW silent genset Manufacturer: Jiangsu Starlight Electricity Equipments Co.,Ltd Output power: 300kw/375kva Frequency/speed: 50Hz/1500rpm Voltage: 230/400V Power fac...

How to prevent emergency generator from burning out

Today Starlight Power introduces how to prevent emergency diesel generator set from burning out. Hope it is helpful for everybody. 1.Keep diesel generator set clean. In the operation of diesel generator set, if dust, water stains and other debris enter into the diesel generator set, it will form short-circuit medium, which can damage the insulation layer of conductor and form turn to turn short circuit. With the increase of current and temperature, the diesel generator set will be burned. Therefore, we should prevent dust, water stains and other debris from entering into diesel generator set. At the same time, we should also often clean the exterior of diesel generator set. Do not let dust and other sundries exist in the cooling rib of diesel generator set, so as to ensure the heat dissipation of diesel generator set. 2.Frequent inspection, listen carefully, when smell something, immediately shut down. Check the diesel generator set for vibration, noise and abnormal smell. In the opera...

The Second Belt and Road Forum for International Cooperation (BRFIC) Was Held in Beijing

Yuchai, as a representative of the national power, provides transportation service support for the forum. The second Belt and Road Forum for International Cooperation (BRFIC), with the theme of "Working Together to Deliver a Brighter Future for Belt and Road Cooperation", was held on April 25-27 in Beijing. Powering the Implementation of the "Belt and Road" Initiative According to reports, there were a total of 457 buses equipped with Yuchai YC6L engines serving the second BRFIC, including 62 Shouqi buses, 185 BAIC buses and 210 Crescent buses. This engine model features reliable performance and rich operation experience. It is a star model equipped for buses serving important events in foreign affairs and shuttle buses serving VIPs. With star products, there must also be a star support team. Yuchai' support team has a total of 25 members including service engineers from Yuchai's Headquarters, personnel from Yuchai's Beijing office an...

Cummins Engine Maintenance - Starlight Power

Engine fuel requirements Fuel: – Use high quality light diesel oil of temperature 0 or lower – Using higher temperature fuel will clog the filter to reduce power – Use higher temperature fuel to make engine starting difficult – Drain the water from the fuel filter in the hot state after shutdown – Replace filters regularly (250h) – If the fuel used is dirty, the filter will be blocked in advance. – Engine power will drop after the filter is clogged. Engine oil requirements lubricating oil: – Viscosity meets SAE 15W40 – Quality meets API CD or higher rating – Change oil and filter regularly (250h) – Must use CF4 or above oil on the plateau – The combustion condition of the engine in the plateau deteriorates, the oil pollution is very fast, and the oil life below the CF4 level is less than 250h. – Exceeding the life of the engine will result in the engine not being properly lubricated, the wear will be intensified, and early failure will o...

Fault tracing of Volvo Power Generation Engine TAD734GE

Diagnostic function The diagnostic function monitors and checks that Volvo Engine EMS 2 system functions normally. The diagnostic function has the following tasks: • Detect and locate functional faults • Inform that a functional fault has been detected • Give guidance during fault tracing Fault code If the diagnostic function discovers a fault in the EMS -2 system, this is indicated via the fault code/fault reason on the instrument. Both active (unrectified) and passive (rectified) faults are registered in the control system. Refer to heading “Running” to read off fault codes/fault messages. The fault code list contains all the fault codes and fault messages, together with information about causes, reactions and remedies that should be taken. Refer to chapter “Fault codes”. NOTE: All instruments are options Active faults DCU (Display Control Unit) • the text “!! ENGINE WARNING !!” is shown on the display. NOTE: You can select the language ...