How to Operate Perkins Generator in Winter?


To operate Perkins generator smoothly in winter, some things need to be noted. For example, a low temperature start method, a choice of lubricating oil, a need for a water jacket heater, and the like. Please refer to the following information for details.

The low fuel temperature in winter makes the viscosity of diesel oil increase and the fluidity deteriorates, which causes the diesel to be difficult to spray, resulting in poor atomization and even deterioration of combustion, which makes the diesel engine's power and economic performance decline. Therefore, light diesel oil with low freezing point and good ignition performance should be selected in winter. It is generally required that the freezing point of diesel engine should be lower than the local current season temperature 7 - 10°C.



Use an open flame to start the machine  where the temperature is too low, but do not remove the air filter. After the cotton yarn is ignited on the diesel oil, the igniter is placed in the intake pipe to perform the combustion-supporting start. In this way, during the starting process, the external dusty air will be directly sucked into the cylinder without filtering, causing abnormal wear of pistons, cylinders, etc., and the emergency standby Perkins generator set will be rough and damage the machine.

If the water is discharged too early or does not discharge cooling water, the generator will run at idle speed before stopping. When the temperature of the cooling water drops below 60°C, the water is not hot, turn off and discharge water. If the cooling water is released too early, the body will suddenly shrink and crack when it is attacked by cold air at a high temperature. When releasing water, the remaining water in the body should be drained to prevent it from swelling and causing the body to burst. It is recommended that the generator set user use antifreeze in any season. Because the antifreeze not only acts as a cooling, but also protects the diesel engine.

Selection of lubricating oil. The oil with low freezing point should be used in winter. When starting, the temperature of the oil can be increased by using the external water bath heating method. It is not recommended to use an open flame to avoid deterioration or even burning of lubricating oil in the oil pan, which will cause lubrication performance to reduce or loss, and aggravate the wear of the machine.

To start the generator set in winter, a water jacket heater should be assembled to the generator to keep the machine "body temperature" and easy to operate. Some operators to start Perkins generator, often use no water start (start first, then add cooling water) abnormal start method. This practice will cause serious damage to the machine and should be prohibited. The correct preheating method is: firstly cover the heat preservation hood on the water tank, open the drain valve, continuously inject 60-70°C clean soft water into the water tank, and touch the water flowing out of the drain valve, if you feel the water is hot, close the drain valve, and then start again.

Low temperature load precautions. After the emergency backup Perkins generator set started to fire, some operators could not wait to put into the load operation. Diesel engine that is on fire for a short time, because of the low temperature of the body, the viscosity of the oil is large, and the oil is not easily rushed into the moving friction surface, causing serious wear and tear on the machine. In addition, the plunger spring, the valve spring and the injector spring are also easy to break due to "cold brittleness". Therefore, after the diesel generator starts to catch fire in winter, it should be idling at low and medium speed for a few minutes, and the temperature of the cooling water reaches 60°C, and then put into load operation.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...