Skip to main content

Main Features of Perkins Generators


Perkins is a British based company that is one of the top diesel generator manufacturing companies in the world. With parts and service centres located worldwide.

Perkins Generators (engines) was founded in 1932, offering diesel and natural gas as their base fuels for their engines.  They are very popular in the market due to their economy, reliability, and durability.

The majority of Perkins Generators uses diesel engines to drive the generator thus converting the diesel energy into electrical energy or power.

Perkins Generators are suitable for commercial, construction, industrial, agricultural and residential power generation and there is sure to be a Perkins Generator to suit your needs.

Perkins Generators are known for providing high-quality generators with a lot of efficiency and reliability.



Main Features of Perkins Generators:

An engine driving cooling fan with protection guard.
Fuel lubricating oil and air filter with restriction indicator.
High engine temperature
Detailed user manual
Radiator Stone Guard
Mechanical governing at 1500/1800 RPM.
Low oil pressure
Anti-vibration mountings
Load & Function Tests

Reasons to Buy a Perkins Generator:

Perkins Generators provide models that are composed of a Perkins diesel engine and a quality alternator such as Leroy-Somer.

They are designed with 12V DC supply motor and storage battery.

The engine cooling system in this generator is the water-cooled system.
Trailer Perkins generators adopt an 8-hour operation base tank.

Perkins generators have a comprehensive range of Electropak specifications that are complete and ready to run.

For regulated countries, the power ratings are available up to 600KW and 1500KW for less regulated locations.

Perkins has a dedicated range of engines which offer the highest fuel efficiency meaning very low running costs.

Perkins generators can come as an open-set or with an acoustic container to reduce noise pollution.

New Perkins generators are available with a standard warranty of up to 2 years.

Starlight Perkins series diesel generator 50Hz/60Hz is available according to different engine models. If you are interested, send us email: sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The