Treatment of Slow Engine Shutdown in Diesel Generator Sets

 What should we do when we find that the diesel generator set engine is slowly stalling? Firstly, check whether there is oil in the fuel tank of the diesel generator set and whether the vent valve of the fuel tank cap is unobstructed. Qualified fuel will not contain impurities and moisture when leaving the factory, but will be mixed with dust, dirt, and moisture to some extent during transportation and storage.


diesel generator set


Loosen the bleed screw of the fuel injection pump, pump oil with a hand pump, and observe the oil flow at the bleed screw. If there is no oil flowing out, it means that the oil circuit is blocked, and it should be checked and eliminated section by section. If diesel is emitted in a spray column, it indicates that the oil circuit is unobstructed. If there are bubbles emerging from the vent screw, it indicates that air has entered the pipeline. It is necessary to check whether the joints of the oil pipe are tightened, whether there are cracks or abrasions in the pipeline, and eliminate any problems found. Timely maintenance should be carried out, and severe damage should be replaced. If there are no bubbles in the oil flow, the hand oil pump can be returned and fixed, and the starter can be used to drive the engine to rotate the pump oil. If there is still no oil flowing out, it indicates that the fuel transfer pump is faulty.


After the above operations, diagnose and handle the slow engine shutdown of the diesel generator set, and perform routine maintenance on the diesel generator set, such as daily maintenance, monthly maintenance, quarterly maintenance, annual maintenance, and break-in period maintenance. The content and timing of planned maintenance are related to the working hours of the unit, such as first level maintenance, second level maintenance, and third level maintenance. In planned maintenance, regular maintenance refers to the mandatory execution of maintenance tasks according to the plan.


Since 1982, Dingbo Generator has been a generator set manufacturer qualified by the "National Internal Combustion Engine Quality Supervision and Inspection Center". The product quality has passed the IS09001 quality system standard certification. And obtained the qualification certificate for self-operated import and export. Over the years, Dingbo units have been widely used in all walks of life, and have won the network access qualification of the Ministry of Information Industry, the network access qualification of the Ministry of Radio and Television, the network access qualification of CNPC, the network access qualification of China Mobile, and the manufacturing qualification of marine units. In 2016, Dingbo was awarded the Certificate of Qualified Supplier of China Nuclear Power Group. Dingbo Generator has been cooperating with Shangchai Power for many years. In 2009, it became the OEM partner of Shangchai Power in China. Dingbo generator VOLVO unit ranks the top three in the Asia-Pacific sales volume, and is the core OEM partner of Sweden Volvo in the Asia-Pacific region. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...