Pressure Detection of Oil Delivery Pump for Diesel Generator Sets

Do you know how to operate the oil delivery pressure detection of the diesel generator set oil delivery pump? When detecting the oil delivery pressure of the oil delivery pump, the oil delivery pump can be installed on the diesel generator set, and an oil pressure gauge can be connected in series between the oil delivery pump and the diesel filter to start the diesel generator set. When the normal speed is reached, the pressure change on the oil pressure gauge should be observed. When the speed is above 600 revolutions per minute, the oil pressure should not be less than 147KPA. When the speed is 750 revolutions per minute, the working pressure is 205KPA, and the oil delivery pump should be able to continuously supply oil.


containerized generator


And the fuel supply should not be less than 250ML per minute. If the pressure is too high, it indicates that the fuel pump spring is too tight, and the pressure regulating valve or filter is not working properly. If the pressure is too low, it indicates that the return spring of the fuel pump is too weak or the sealing between the main chamber plunger and sleeve is poor. Both of the above situations should be promptly identified and eliminated.


Plunger type oil delivery pump, also known as piston type oil delivery pump, is widely used in multi cylinder diesel generator sets. Taking the 4135 diesel generator set as an example, the method to determine its good sealing performance is to block the oil receiving hole of the hand oil pump with the palm of your hand when checking the hand oil pump, pull up and down the hand oil pump button, and if you feel a large suction force in the palm, it indicates that the hand oil pump has good sealing performance, operates normally, and can continue to be used.


When testing the oil suction performance of the oil transfer pump, tighten the button of the hand oil pump, install a rubber hose with a diameter of 2m and 8mm at the bolt of the oil inlet joint of the oil transfer pump, and place a container containing clean light diesel oil 1m below the oil outlet of the oil transfer pump. Insert the hose into the container, operate the hand oil pump at a pumping speed of 60 times per minute, and observe whether the oil transfer pump absorbs and pumps diesel oil. If the hand oil pump pumps more than 120 times, The fuel transfer pump has not yet sucked in or pumped out diesel, indicating poor oil absorption performance. It should be repaired or replaced in a timely manner.


Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd is an early professional manufacturer of generators and diesel generator sets in China. The company has first-class national-level large-scale production and load testing equipment. Provide users with long-term diesel generator set sales, leasing, technical consultation, commissioning, maintenance, training services and generator set trusteeship business. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...