Skip to main content

Ways to Eliminate the Fault of Generator Set Cylinder Cushion

Cylinder flushing pad is a common fault in generator sets, and there are various forms of cylinder flushing pad, with the common feature being abnormal noise. Due to the varying degrees of impact on the cylinder cushion, the abnormal sound generated is also different. This article explains the troubleshooting methods based on the varying degrees of cylinder cushion faults in three Hongqi 120 bulldozer generator sets.


standby genset


When a bulldozer is cold started, there are two knocking sounds of "dang" and "dang", and a white smoke is emitted first. The generator set catches fire only after black smoke is emitted. When suddenly increasing the throttle, there is also a knocking sound, and after the throttle stabilizes, the abnormal sound basically disappears. If there is still a knocking sound when suddenly increasing the throttle repeatedly. During the cylinder cutout inspection, it was found that the abnormal noise occurred in cylinder VI. Suspect that the fuel injector needle is stuck. Dismantle and inspect, the results are normal. When removing the VI cylinder head, it was found that there was black smoke burning on the cylinder gasket. It turned out that the cylinder head bolts were very tight (with a torque of 250N · m), but the cylinder head and gasket could not be pressed tightly because there was a water blockage on the body that was higher than the upper plane of the body. Replace the cylinder gasket and ensure that the water blockage height is lower than the upper plane of the engine body. After reinstallation, the abnormal noise disappears and the generator set operates normally.


The phenomenon of another bulldozer is that the generator set makes a "honk, honk" sound when idling. When the fuel supply of the V cylinder is cut off, the sound weakens until it disappears. I once suspected that it was caused by a large amount of idle oil in the V cylinder, but reducing it was of no use. When the large and medium oil valves are running, the abnormal noise is not obvious. The valve clearance is normal. When starting the generator set and forcefully increasing the throttle, there is a knocking sound of "dang, dang", repeatedly increasing the throttle, and smoke comes from the V-cylinder gasket. After inspection, it was found that the faults were all caused by the flushing of the cylinder gasket.


There is also a bulldozer that makes a noticeable noise when loaded. When the throttle is small and unloaded. The abnormal noise is not obvious. When the load is repeatedly applied, the sound is obvious and there is air escaping between the cylinder heads of cylinders III and IV. Cylinder cutout inspection found. The III cylinder gasket was burned. After replacing the cylinder gasket, the problem was resolved.


The Hongqi 120 bulldozer is equipped with a 6130 diesel engine (one cylinder, one cover). There are relatively few failures of cylinder head gasket, most of which are caused by the cylinder head bolts not being tightened according to the specified torque and sequence (2-3 times).


Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Baudouan Weichai 1530KW Diesel Generator Set 16M33 Series Engine

Weichai is the earliest enterprise in China to develop and produce generator sets, with a production history of over 60 years. It mainly produces land - based and marine generator sets, including diesel - type and gas - type units. Weichai's M33 series engines include 6M33, 12M33, and 16M33 diesel engines. These are high - power high - speed diesel engines independently developed by Weichai based on the mature product platform of Baudouin's M26 series in France. The development of this series of models fills the gap in Weichai's high - speed diesel engines for power generation in the 500 - 1530kW power range, enabling effective competition with foreign brands. The M33 series Weichai engines inherit and carry forward the advanced product development and design concepts of the French Baudouin M26. They are benchmarked against international advanced engines, effectively avoiding various design defects. The product development emphasizes high reliability and low emissions. Th...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...