Skip to main content

Precautions for The Diesel Generator Set Use on Construction Site

Due to its small size, convenient handling, fast power supply, long service life and simple operation, diesel generator sets have been used in various fields, such as standby power supply in factories, fire emergency power supply in real estate, and supplementary power supply in construction site. In order to improve work efficiency and ensure safe production, Dingbo Power will talk with you about what we should pay attention to when using diesel generator sets in the construction site. The specific content is as follows:


power generation


When the diesel generator set is under construction on the construction site, Dingbo Power reminds the user of the following matters:


1. During site construction, the rated voltage of the diesel generator set must be consistent with the power supply voltage, frequency and other parameters of the electrical equipment used.


2. The installation environment of the diesel generator set on the construction site shall be close to the load center, with convenient incoming and outgoing lines, smooth surrounding roads, and away from the downwind side of the pollution source and places prone to ponding.


3. The fixed diesel generator set on the construction site shall be installed on the basis of indoor compliance and shall be 0.25 to 030 m higher than the indoor ground. The mobile diesel generator set should be in a horizontal state and placed firmly. Its trailer should be reliably grounded, and the front and rear wheels should be stuck. The diesel generator set used outside the construction site due to limited conditions shall be provided with protective shed.


4. The power supply of the diesel generator set must be interlocked with the power supply of the external power line, and parallel operation with the external power line is strictly prohibited; When two or more diesel generator sets operate in parallel, synchronization device must be installed, and power shall be supplied to the load after the units are synchronized.


5. The diesel generator set and its control, power distribution, repair room, etc. shall be set to ensure electrical safety distance and meet fire protection requirements; Smoke exhaust pipes should extend outdoors and it is strictly prohibited to store oil storage drums indoors or near exhaust pipes.


The above content is what Dingbo Power Generation Equipment has shared with you about the matters needing attention in the construction of the diesel generator set at the project site. You should refer to the above content to do a good job in the inspection of the diesel generator set, to ensure the stability of the construction power supply at the project site, and not delay the project progress due to the failure of the generator set.


Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd is an early professional manufacturer of generators and diesel generator sets in China. The company has first-class national-level large-scale production and load testing equipment. Provide users with long-term diesel generator set sales, leasing, technical consultation, commissioning, maintenance, training services and generator set trusteeship business. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...