Why Does My Generator Fuel Injection Pump Not Supply Oil?


The main reason why the diesel generator set fuel injection pump does not supply oil

1. There is no oil in the fuel tank or the oil switch is not open.

2. The diesel filter is clogged.

3. There is a lot of air in the oil road.

4. The plunger of the fuel injection pump is broken.

5. The plunger couple is excessively worn.

6. The plunger is stuck.

7. The screw groove of the plunger is installed in the wrong position.

8. The oil outlet valve is excessively worn or dirty.

9. The spring of oil outlet valve is broken or the spring force is weakened.

10. The plane contact between the oil outlet valve and the plunger sleeve is not strict, which causes the diesel oil to leak from the gap in the contact surface. The fuel valve is not opened at the top and the fuel injection pump is not supplied with oil.

11. The oil outlet valve is broken.


Inspection method: If all cylinders do not supply oil, the diesel engine cannot work. If the individual cylinder does not supply oil, the diesel engine is difficult to start, even if started, the work is not stable. After finding this fault, first check if there is oil in the diesel tank, whether the fuel tank switch is open, and whether the vent hole of the fuel tank is blocked. Then unscrew the bleeder screw of the diesel filter and the fuel injection pump, pump the oil with the hand fuel pump or self-flow by the gravity of the diesel fuel. If there is air bubble in the diesel oil flowing out at the bleeder screw, it indicates that there is air in the oil pipeline. It should be found out that the reason is insufficient diesel oil in the fuel tank or the oil pipe joint is loose or the oil pipe is broken and the gaskets are not tight. After troubleshooting, continue to pump oil by hand oil pump or rely on the gravity of diesel to flow freely until there is no air bubble in the diesel oil. Then tighten the bleeder screw and the hand pump.

If the oil is pumped by the hand oil pump or the gravity of the diesel oil flows, it is felt that the oil is not smooth, indicating that the low pressure oil circuit is blocked. Check whether the diesel filter and the low pressure oil circuit are blocked. If there is oil leakage in the low pressure oil circuit, it will also cause the diesel oil to be blocked.

If there is no problem after inspection, the fault is inside the oil pump and should be disassembled and inspected. If there is no problem with the oil pump, the fault is on the fuel injection pump.


For the combined fuel injection pump, the side cover of the fuel injection pump can be removed here, the throttle handle is placed at the stop oil supply position, and the plunger spring seat of the fuel injection pump is pried by the screwdriver to perform the pump oil action, check whether the plunger spring is broken and whether the plunger is stuck.

At the same time, it should also check whether the screw that adjusts the ring gear is loose, resulting in changes in oil supply. If the inspection is good, check the wear degree of the plunger couple and the sealing of the oil outlet valve.

Comments

Popular posts from this blog

Baudouan Weichai 1530KW Diesel Generator Set 16M33 Series Engine

Weichai is the earliest enterprise in China to develop and produce generator sets, with a production history of over 60 years. It mainly produces land - based and marine generator sets, including diesel - type and gas - type units. Weichai's M33 series engines include 6M33, 12M33, and 16M33 diesel engines. These are high - power high - speed diesel engines independently developed by Weichai based on the mature product platform of Baudouin's M26 series in France. The development of this series of models fills the gap in Weichai's high - speed diesel engines for power generation in the 500 - 1530kW power range, enabling effective competition with foreign brands. The M33 series Weichai engines inherit and carry forward the advanced product development and design concepts of the French Baudouin M26. They are benchmarked against international advanced engines, effectively avoiding various design defects. The product development emphasizes high reliability and low emissions. Th...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...