Skip to main content

Methods to Control Sand in Desert Area for Diesel Genset


How to control sand for diesel generator set in desert area?

The sand control measures are mainly aimed at the air inlet end of the unit, that is, the air intake valve. There is an air filter element at the air inlet end of the unit, but this can only be satisfied with the general environment. In order to avoid the large amount of dust into the engine body, causing early wear of diesel generator set. We can cover the cap of the air filter element with a fine hole gauze to prevent sand.

What should we pay attention to the use of diesel generator set in desert area?

When operating the unit.

1.After starting the diesel engine, it should idle for 3-5 minutes, and then rise to the rated speed, do not suddenly make it run at high speed.

2.When the diesel generator set is in working condition (with high temperature), it is forbidden to open the water tank cover to avoid scalding.

3.To prevent the components from getting involved in the machine. It is forbidden to start the generator set after the protective net of the generator set is removed.

4.Observe the water temperature and oil pressure at any time during the operation of the unit. Stop the unit if the water temperature is higher than 100 or the oil pressure is lower than 0.1.

When stopping the unit.

1.Slow down the speed and stop the unit after idling for 3-5 minutes.

2.When the ambient temperature is lower than 0, drain the water in the water tank, diesel engine body and oil cooler.

Special attention.

1.The generator air switch (circuit breaker) must be disconnected before starting and stopping. It is strictly prohibited to start or stop the unit when it is loaded.

2.It is forbidden to operate the diesel engine for too long time(no more than 15 minutes) without load.

Some users think that although in desert area, but the generator set is used in the machine room and will not be affected by the wind and sand, so they do not protect the unit against sand. In fact, this is a unilateral idea. Even indoors, the amount of windblown sand in the air in desert areas is much higher than that in general areas. The air filter element of the unit can not completely isolate these sandstorms, so in order to protect your unit, you must carefully implement the above sand prevention measures.

Our diesel generator sets are sold to all over the world, also many clients buy unit for desert areas. Therefore, we recommend more suitable units to customers according to the site where they use diesel generators.

How to configure parts of diesel engine and alternator in desert areas?

1.Heavy duty air filter. To prevent excessive dust in the air from affecting the engine.

2.Alternator filter net. Prevent the dust in the air from entering the electric ball, which will reduce the power by 5%.

3.Diesel filter and primary filter. To prevent dust in the air from entering the fuel system.

The above optional products can effectively prevent dust damage to the alternator or engine.

Diesel generator set for desert is one of many special condition generator sets. In addition, we should pay attention to the selection and matching of diesel generator set under high temperature and high altitude conditions. For these conditions, we also can provide effective solutions.

Starlight Power is a manufacturer of diesel generators with more than 43 years’ experience. If you plan to purchase generator set for desert areas or others, but do not know how to do, welcome to contact us(sales@dieselgeneratortech.com). Professionals will answer for you.


Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...