Skip to main content

250KVA Perkins Diesel Generator - Standby Generator



Dependable power

1. The 1506A-E88TAG2 delivers greater productivity through an improved power to weight ratio.

2. The world-class power density has been achieved from an 8.8 litre turbocharged engine using a hydraulic actuated unit injection (HEUI) fuel system; making this engine robust for all markets due to its ability to cope with the variation of fuel quality around the world

3. In its class, the 1506A-E88TAG2 has been designed to provide dependable power even in extreme ambient climates.

Low operating costs

1. Oil change service intervals are set at 500 hours as standard.

2. Designed to provide low cost of ownerhsip, simple maintenance and reduced downtime.

3. 12 months unlimited warranty with 24 months on Major items. For low use applications <500 hours per year warranty is extended by a further 12 months. See Perkins Warranty Policy for further details.

Flexibility

1. The 1506-E88TAG2 has been designed to hit the power node requirements of customers.

2. Switchability functionality from 50 Hz/1500 rpm to 60 Hz/1800 rpm and vice versa is available to provide greater flexibility for frequency selection.

World class product support

1. Experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their disposal, covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine.

2. Perkins actively pursues product support excellence by insisting our distribution network invest in their territory to provide customers with a consistent quality of support across the globe

3. Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts giving 100% reassurance that you receive the very best in terms of quality for lowest possible cost, wherever your Perkins powered machine is operating in the world.



Perkins 1506A-E88TAG2 Generator Engine

Technical information

Air inlet system - Mounted air filter and turbocharger

Fuel system

1. HEUI fuel system with full authority electronic control
2. Electronic governing to ISO 8528-5 with stand-alone isochronous and load-sharing capabilities
3. Fuel filter, fuel transfer pump, fuel priming pump
4. Spin on primary, secondary and water filter separator

Lubrication system
1. Wet full aluminium sump with filler and dipstick
2.  Full-flow spin-on filters
3. Oil pump, gear driven

Cooling system
1. Thermostatically controlled with belt driven, circulating pump and belt-drive fan
2. Mounted belt driven pusher fan
3. Radiator supplied loose with all guards and pipes
4. Air-to-air charge cooler incorporated in radiator

Electrical equipment
1. 24V starter motor and 24V, 45 amp alternator with DC output
2. Electronic Control Module (ECM) mounted on engine with wiring looms and sensors

Flywheel and housing
1. High inertia flywheel to SAE 1 J620 Size 355.6 mm (14 in)
2. Aluminium SAE 1 flywheel housing
Mountings - Front engine mounting bracket

Perkins Diesel Generator Maintenance

1. Perkins diesel generator needs to change oil, clean diesel filter and air filters after 60 hours of operation.

2. The electrolyte of the battery should be checked frequently and replenished in case of shortage.

3. Should always check the tightness of the belt, adjust the tensioning mechanism to maintain the tensioning state.

4. In the cold season, the water heating and oil heating switches should be turned on to keep the genset at a certain temperature to ensure the normal use of the diesel generator set.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Baudouan Weichai 1530KW Diesel Generator Set 16M33 Series Engine

Weichai is the earliest enterprise in China to develop and produce generator sets, with a production history of over 60 years. It mainly produces land - based and marine generator sets, including diesel - type and gas - type units. Weichai's M33 series engines include 6M33, 12M33, and 16M33 diesel engines. These are high - power high - speed diesel engines independently developed by Weichai based on the mature product platform of Baudouin's M26 series in France. The development of this series of models fills the gap in Weichai's high - speed diesel engines for power generation in the 500 - 1530kW power range, enabling effective competition with foreign brands. The M33 series Weichai engines inherit and carry forward the advanced product development and design concepts of the French Baudouin M26. They are benchmarked against international advanced engines, effectively avoiding various design defects. The product development emphasizes high reliability and low emissions. Th...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...