Skip to main content

250KVA Perkins Diesel Generator - Standby Generator



Dependable power

1. The 1506A-E88TAG2 delivers greater productivity through an improved power to weight ratio.

2. The world-class power density has been achieved from an 8.8 litre turbocharged engine using a hydraulic actuated unit injection (HEUI) fuel system; making this engine robust for all markets due to its ability to cope with the variation of fuel quality around the world

3. In its class, the 1506A-E88TAG2 has been designed to provide dependable power even in extreme ambient climates.

Low operating costs

1. Oil change service intervals are set at 500 hours as standard.

2. Designed to provide low cost of ownerhsip, simple maintenance and reduced downtime.

3. 12 months unlimited warranty with 24 months on Major items. For low use applications <500 hours per year warranty is extended by a further 12 months. See Perkins Warranty Policy for further details.

Flexibility

1. The 1506-E88TAG2 has been designed to hit the power node requirements of customers.

2. Switchability functionality from 50 Hz/1500 rpm to 60 Hz/1800 rpm and vice versa is available to provide greater flexibility for frequency selection.

World class product support

1. Experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their disposal, covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine.

2. Perkins actively pursues product support excellence by insisting our distribution network invest in their territory to provide customers with a consistent quality of support across the globe

3. Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts giving 100% reassurance that you receive the very best in terms of quality for lowest possible cost, wherever your Perkins powered machine is operating in the world.



Perkins 1506A-E88TAG2 Generator Engine

Technical information

Air inlet system - Mounted air filter and turbocharger

Fuel system

1. HEUI fuel system with full authority electronic control
2. Electronic governing to ISO 8528-5 with stand-alone isochronous and load-sharing capabilities
3. Fuel filter, fuel transfer pump, fuel priming pump
4. Spin on primary, secondary and water filter separator

Lubrication system
1. Wet full aluminium sump with filler and dipstick
2.  Full-flow spin-on filters
3. Oil pump, gear driven

Cooling system
1. Thermostatically controlled with belt driven, circulating pump and belt-drive fan
2. Mounted belt driven pusher fan
3. Radiator supplied loose with all guards and pipes
4. Air-to-air charge cooler incorporated in radiator

Electrical equipment
1. 24V starter motor and 24V, 45 amp alternator with DC output
2. Electronic Control Module (ECM) mounted on engine with wiring looms and sensors

Flywheel and housing
1. High inertia flywheel to SAE 1 J620 Size 355.6 mm (14 in)
2. Aluminium SAE 1 flywheel housing
Mountings - Front engine mounting bracket

Perkins Diesel Generator Maintenance

1. Perkins diesel generator needs to change oil, clean diesel filter and air filters after 60 hours of operation.

2. The electrolyte of the battery should be checked frequently and replenished in case of shortage.

3. Should always check the tightness of the belt, adjust the tensioning mechanism to maintain the tensioning state.

4. In the cold season, the water heating and oil heating switches should be turned on to keep the genset at a certain temperature to ensure the normal use of the diesel generator set.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...