Characteristics of Baudouin Power Generation Engine



Good economy
Pre-filtered air filter: greatly extend the maintenance and replacement cycle of the air filter element
Three-level babysitter filter: fuel filter replacement cycle up to 400h
Centrifugal rotor filter: oil filter replacement cycle up to 400h
Fuel consumption rate is better than competing products



High reliability
Body, cylinder head, crankshaft and connecting rod:
High-strength design, improve the reliability of the whole machine, long overhaul period
Overhaul period: design life 32000h

Good NVH performance
Injection molding air filter: light weight, reduce engine vibration
Casting oil pan: high strength, reduce vibration noise

Easy to start at low temperature

High compression ratio: effectively increase the compression termination temperature.
Electric fuel pump: automatic emptying can be realized.
Intake heating device: ensure normal starting of engine at-20
Baudouin 6M33D starts smoothly at -20°C without other preheating devices.
6M33D is equipped with water boiler and oil heating rod, which starts smoothly at-41 ±2.

Good plateau adaptability
1. Supercharger selection: engine development takes into account plateau performance;
2. ECU automatically adjusts the fuel supply advance angle;
3. CAE simulation: simulation of plateau conditions for calculation and analysis;
4. Three-high test: the performance of diesel engine was checked at high altitude.

The engine power is defined as follows:

Prime rated power (PRP):
1. The annual running time is not limited;
2. The average load rate should not exceed 70% for each 250h duration;
3. Run no more than 500h per year under 100% load;
4. Within 12h, it can be overloaded for 10% for 1h, and the accumulated overload operation for no more than 25h per year.

Emergency standby power (ESP):
1. The annual running time does not exceed 200h, including no more than 25h per year under 100% load;
2. The average load rate does not exceed 80% every 24h operation cycle;
3. Does not have overload capacity.

Starlight Power can provide 400KW to 3000KW prime & emergency standby diesel power generators with Baudouin engine. (China Non-Road Emission Stage III standard.) If you are interested, contact us by email: sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...