Characteristics of Baudouin Power Generation Engine



Good economy
Pre-filtered air filter: greatly extend the maintenance and replacement cycle of the air filter element
Three-level babysitter filter: fuel filter replacement cycle up to 400h
Centrifugal rotor filter: oil filter replacement cycle up to 400h
Fuel consumption rate is better than competing products



High reliability
Body, cylinder head, crankshaft and connecting rod:
High-strength design, improve the reliability of the whole machine, long overhaul period
Overhaul period: design life 32000h

Good NVH performance
Injection molding air filter: light weight, reduce engine vibration
Casting oil pan: high strength, reduce vibration noise

Easy to start at low temperature

High compression ratio: effectively increase the compression termination temperature.
Electric fuel pump: automatic emptying can be realized.
Intake heating device: ensure normal starting of engine at-20
Baudouin 6M33D starts smoothly at -20°C without other preheating devices.
6M33D is equipped with water boiler and oil heating rod, which starts smoothly at-41 ±2.

Good plateau adaptability
1. Supercharger selection: engine development takes into account plateau performance;
2. ECU automatically adjusts the fuel supply advance angle;
3. CAE simulation: simulation of plateau conditions for calculation and analysis;
4. Three-high test: the performance of diesel engine was checked at high altitude.

The engine power is defined as follows:

Prime rated power (PRP):
1. The annual running time is not limited;
2. The average load rate should not exceed 70% for each 250h duration;
3. Run no more than 500h per year under 100% load;
4. Within 12h, it can be overloaded for 10% for 1h, and the accumulated overload operation for no more than 25h per year.

Emergency standby power (ESP):
1. The annual running time does not exceed 200h, including no more than 25h per year under 100% load;
2. The average load rate does not exceed 80% every 24h operation cycle;
3. Does not have overload capacity.

Starlight Power can provide 400KW to 3000KW prime & emergency standby diesel power generators with Baudouin engine. (China Non-Road Emission Stage III standard.) If you are interested, contact us by email: sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...