Skip to main content

Perkins 4000 Series Engine Models And Features

In this article, we mainly introduce Perkins 4000 Series engine features and models.

Technical Service - Global Distribution & Service Network


In 1985, Perkins celebrated engines production of 10,000,000 units. And in 1998, Caterpillar Inc purchased Perkins Engine Company Limited with $1.3 billion, creating the world’s largest diesel engine manufacturer.

So far, it has provided the global with 15 million gensets ranging from 4 KW to 1940 KW; it currently has three production bases, with an annual production of 400,000 sets; the company has established two parts release center in Manchester, England and Singapore and set up more than 3500 service outlets worldwide, which provide worldwide customers with uninterrupted service throughout the year.





Product Advantage:

1. 23 to 61 litre.
2. In-line 6 and 8 cylinder, V 12 and 16 cylinder.
3. Electronic governing for excellent load response and fuel consumption.
4. Excellent service access for easy maintenance.
5. Common Components, Convenient repair.
6. 50HZ/60HZ switchable engines to meet different market requirements.
7. Emissions variants, EU2 capableGerman TA Luft 1986 capable.
8. Twin actuators introduced on all 4016 models, engine operates on 1 bank at low load can improve emissions, smoke characteristic, engine response, better engine control and fuel consumption reduction.
9. Warranty, continuous power: 1year/no limited; prime: 2 years/6,000H; Standby: 3 years/1500H.

Prime power
1) Total use is lower than 6000 hours in the first year, warranty period extends to the second year or 6000 hours which is the first occur.
2) Total use is over 6000 hours in the first year, warranty period is one year.
Standby power
1)Total use of engines is restricted to 500 hours or less per annul, the engine warranty will be extended into a second year and shall last the end of the second year or until total use reaches 1000 hours, whichever is the first to occur. Note: In cases where the total use of *4000 Series engines is restricted to 500 hours or less per annul, the engine warranty will be extended into a third year and shall last until the  end of the  third year or until total use reaches 1500 hours, whichever is the first to occur.
2) Total use of engine is over 500 hours in the first year, engine warranty time is two years or 6000 hours which is the first to occur.
3)Total use of engine is over 1000 hours in the second year, warranty period is 2years.
10. Load acceptance, up to 73% first load step Engine.



4000 Series  Key Engine Models



Engine   Model



Speed

Genset   Prime Power
Engine   Output Power


Control   Mode
KW
KVA
KW
4006-23TAG2A       
1500
600
750
632

Electric
4006-23TAG2A  
1500/1800
4006-23TAG3A  
1500
640
800
679
4008TAG1A      
720
900
767
4008-30TAG1    
758
4008-30TAG2    
800
1000
842
4008TAG2A      
861
4008TAG2A       
1500/1800
4008-30TAG3    
1500
900
1125
947
4012-46TWG2A 
1000
1250
1055
4012-46TWG2A 
1500/1800
4012-46TAG2A  
1500
1200
1500
1267
4012-46TAG2A  
1500/1800
1267
4012-46TAG3A  
1500
1368
1710
1440
4016TAG1A       
1480
1850
1537
4016TAG2A       
1600
2000
1715
4016-61TRG1    
1480
1850
1558
4016-61TRG2    
1600
2000
1684
4016-61TRG3    
1800
2250
1875


Note: 1500/1800 shows that it is switchable engine, the power shown in the sheet is under 1500rpm.

Don’t know which brand of generator is reliable? Want to purchase a high quality generating unit? Perkins generator should be the right one.





About Perkins generator maintenance, please refer to the following tips:
1. Changing the oil, cleaning diesel filter and oil filter after diesel generator runs up to 60 hours.
2. Regularly checking the battery electrolyte and adding electrolyte in a timely manner when necessary.
3. Regularly checking belt release situation, adjusting the tension mechanism, and keeping the state of tension.
4. During the cold season, opening the oil heating and water heating switch to keep a certain temperature of generator set, so as to ensure that diesel genset can be normally used.

Comments

  1. Thank you for your comment. We are professional diesel generator manufacturer in China. If any needs, please contact us at: http://www.dieselgeneratortech.com/. Or send us email: sales@deiselgeneratortech.com

    ReplyDelete

Post a Comment

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...