Last week, our company's after - sales department received a repair call. The starting motor of a diesel generator set purchased from our company two years ago couldn't rotate. Our company immediately sent Technician Zhang to conduct maintenance. This kind of fault of the diesel generator set was a piece of cake for the experienced Technician Zhang. After his treatment, the problem was solved on the same day.

The starting motor of a diesel generator set is also called a starter motor. Technician Zhang from Dingbo Power introduced that there are generally two situations for the failure of a diesel engine's starting motor to rotate. One is that the action sound of the electromagnetic switch's engagement can be heard, but the starting motor doesn't rotate. The reasons may be insufficient battery power, poor contact in the starting circuit, or a fault in the starting motor itself. The other is that the electromagnetic switch doesn't engage and the starting motor doesn't rotate. In addition to the above reasons, it may also be related to faults in the starting switch circuit, the electromagnetic switch, or the DC motor.

Fault Cause Analysis of the Starting Motor (Starter) of Diesel Generator Sets

1.Check if the starting motor relay is working.

2.Check if the transmission gear of the starting motor can mesh with the flywheel ring gear of the diesel engine.

3.The starting motor engages, but the diesel engine cannot rotate or rotates weakly.

4.The diesel engine has started, but the starting gear cannot disengage, making a shrill noise.

5.Check if the battery power is insufficient.

6.Check if the battery temperature is too high.

7.Check if the battery case is deformed or the seal is cracked.

Precautions for Using the Motor

Don't start the motor for a long time: If the motor is started for too long at one time, the battery will discharge a large amount of electricity for a long time, which can easily cause the battery plates to bend. Excessive discharge can easily cause sulfation of the plates, rendering the battery useless.

Don't increase the voltage for starting: To increase the motor speed by blindly connecting two batteries in series to supply power to the motor. This not only easily causes the motor to overspeed, generating centrifugal force and accelerating the damage of the bearing bushes, rotor, and stator coils. Moreover, due to the different technical conditions of the two batteries, the good battery will charge the bad one, which can easily damage the good battery.

Don't increase the capacitance for starting: Connecting two batteries in parallel to supply power to the motor doubles the current, generating a large amount of heat. This can easily cause damage and malfunctions to the starting switch, motor contacts, starting wires, rotor, and stator coils.

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...