Diesel generator sets generate a large amount of heat during operation. For the units used in the engine room, the heat is even more difficult to dissipate. Once the diesel generator set operates in an environment with excessively high temperature, its load - carrying capacity will also decline.

There are two cooling methods for diesel generators: air - cooling and water - cooling. When the air - cooling method is adopted, the maximum temperature of the diesel generator room should not exceed 35°C. If there is no condition to build vertical air intake and exhaust ducts in the diesel generator room or the area is insufficient, supply and exhaust fans need to be added to ensure the supply and discharge of air volume, which should be calculated according to the actual situation. When water - cooling is used in the diesel generator room, the air intake volume can be calculated at no less than 20 m³/(kW·h) of the rated power of the diesel engine.

 

Design of the Diesel Generator Set Exhaust System

1.The position of the radiator exhaust fan of the diesel generator set is the exhaust outlet for the unit's heat. There should be good ventilation and no obstruction within 1 meter in front of the radiator. The heat exhausted from the radiator should be directly discharged to the outside. If the heat circulates indoors, it will cause the unit to overheat, affecting its normal operation and even leading to shutdown.

2.The exhaust of the diesel generator set is also a problem that customers need to consider. The exhaust should be directly piped to the outside or an exhaust fan should be installed in the engine room to directly suck the indoor exhaust gas out. Since the exhaust pipe also generates a large amount of heat during the operation of the unit, the generator manufacturer suggests that users should wrap a layer of insulation cotton around the outer layer of the exhaust pipe to prevent the heat from dissipating in the engine room and increasing the indoor temperature.

3.The air intake and exhaust of the unit's engine room should not be in the same position. The air intake and exhaust should be reasonably arranged to ensure smooth air circulation and good heat dissipation.

4.The end face of the unit's radiator is the area where the unit dissipates heat most intensively. The area of the engine room's exhaust outlet should be 1.5 times larger than that of the radiator. A heat - dissipation channel should also be built at the end face of the radiator to facilitate the direct dissipation of heat to the outside and prevent the increase of indoor temperature.

 

The exhaust system of the diesel generator set includes the muffler, bellows, flange, elbow, gasket that come as standard with the engine, and the exhaust pipe connecting the engine room to the outside. The exhaust system of each unit should be independently designed and installed. It is absolutely not allowed for different units to share an exhaust pipe to avoid abnormal movement caused by different exhaust pressures of different units during operation, increase the exhaust back - pressure, and prevent the back - flow of waste smoke and exhaust gas through the shared pipe, which may affect the normal power output of the unit or even cause damage to the unit.

 

As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...