Troubleshooting Small Generator Non Power Generation

Generators, as commonly used backup power sources, play an important role in our lives. However, many users encounter various fault problems when using small generators. For example, what should they do if a small generator fails to generate electricity and how to repair it? Therefore, we need to first understand the reasons for non - power generation and the inspection methods to solve the problems more efficiently and quickly.

Inspection methods for a small generator that starts but fails to generate electricity

1.Measure whether there is actually electricity. Replace the generator's voltmeter.

2.Switch it to automatic or manual mode.

3.Check and correct according to the wiring diagram.

4.You can charge the magnetism by pressing the charging button on the control panel, or use a 12V battery to charge the excitation winding. Connect the positive pole to F1 and the negative pole to F2. If the voltage still cannot be established, reverse the positive and negative poles of the battery and try again.

5.Clean the surface of the collector ring. Sand the end face of the carbon brush so that its arc matches the surface of the collector ring with an area greater than 70%. Increase the spring pressure.

6.Check the carbon brush and the carbon brush holder to ensure that the carbon brush can move freely.

7.Use a multimeter to check the forward and reverse resistance of the diode.

8.Use a multimeter to check if the forward and reverse resistance meets the requirements.

9.Use the 1K gear of a multimeter to check the winding of the generator set and see if the resistance value is too large.

 

Reasons for a small generator's non - power generation

1.The generator overheats.

2.There is an abnormal voltage between the generator's neutral wire and the ground.

3.The generator current is too large.

4.The terminal voltage of the generator is too high.

5.The power is insufficient.

6.The insulation of the stator winding is broken down or short - circuited.

7.The stator core is loose.

8.There is a short - circuit between the iron chips.

9.The generator loses residual magnetism and fails to generate electricity during startup.

10.The excitation reactor of the automatic excitation device overheats.

 

How to repair a small generator that fails to generate electricity

1.Keep a standby battery and charge the magnetism before power generation.

2.Pass a direct current larger than the rated current (for a short time) through the winding for magnetization. The specific current is determined by experiments.

3.Replace the damaged components and repair the faulty circuit.

4.Remove the scale on the contact surface, adjust the brush pressure, and fasten the brush holder.

5.Correct the wiring and charge the magnetism with the correct polarity.

6.Remove the scale on the contact surface, grind the brush, adjust the brush pressure to ensure that the brush is in close contact with the slip ring.

7.Check and repair the broken circuit.

8.Connect the joints well or repair the contact parts of the switch.

9.Find out the reason for the fuse blowing. After confirming that the generator itself and the circuit are normal, replace the fuse with the specified one.

 

As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...