Chongqing Cummins Engine Warranty Regulations 1

The N, K, and M series engine products produced by Chongqing Cummins Engine Co., Ltd. enjoy the same warranty and service commitments as Cummins products globally. Currently, Chongqing Cummins' after - sales service network covers the Chinese mainland, as well as Taiwan, Hong Kong, and Macau regions. There are more than 60 authorized service dealers in China, and nearly a thousand technicians with service qualifications will provide professional service support to customers. At the same time, Chongqing Cummins relies on more than 5,000 service institutions of Cummins globally to provide global after - sales service support. This warranty regulation refers to Cummins' international new - part warranty regulation.

Warranty Scope of Chongqing Cummins Engines

This warranty clause applies to new parts sold by Chongqing Cummins Engine Co., Ltd. (hereinafter referred to as Chongqing Cummins), which are delivered to the first end - user on or after July 1, 2005, and are used in the Chinese mainland area where there is Chongqing Cummins authorized maintenance service.

 

Basic Warranty for New Parts of Chongqing Cummins Engines

This warranty covers any malfunction (warrantable malfunction) of new parts caused by defects in materials or manufacturing processes under normal use and maintenance conditions. The warranty period starts from the date when Chongqing Cummins sells the new parts. From the date when the new parts are delivered to the end - user, the warranty period is one year, 100,000 miles (160,935 kilometers), or 3,600 hours of use, whichever comes first. For rubber - based parts (such as belts, hoses, gaskets, etc.) provided by Chongqing Cummins, if they are delivered to the end - user within two years from the date of sale by Chongqing Cummins Engine Co., Ltd., the warranty period is 90 days.

 

Warranty Start Date for New Parts of Chongqing Cummins Engines

1.The warranty start date of new parts is calculated from the date when the original equipment manufacturer or authorized dealer delivers the new parts to the first end - user (a document indicating the warranty start date must be provided).

2.If the user cannot provide the document indicating the warranty start date of the new parts, the warranty start date of the new parts is calculated from the date of leaving the factory of Chongqing Cummins Engine Co., Ltd. plus 30 days.

 

Extended Warranty for Main Components of Chongqing Cummins Engines

The extended warranty for main components covers warrantable malfunctions of engine cylinder blocks, camshafts, crankshafts, and connecting rods (warrantable parts). Malfunctions of bushings and bearings are not covered by this warranty. This warranty period starts from the expiration of the basic warranty period of the new parts and ends three years from the date when the new parts are delivered to the first end - user, or 300,000 miles (482,805 kilometers), or 10,800 hours of use, whichever comes first.

 

Consumer Products

The warranty for consumer products is a limited warranty. Chongqing Cummins is not responsible for incidental or indirect losses. Any implied warranty applicable to consumer products and the express warranty applicable to the product terminate at the same time. These warranties apply to all owners in the distribution network and continue to apply to subsequent owners before the expiration of the warranty period.

 

If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...