Skip to main content

How to Effectively Dissipate Heat from the Radiator of Silent Diesel Generator

The radiator of a diesel generator is an important component of the generator set, and its main function is to remove the heat generated by the diesel generator through heat dissipation, maintaining the normal operating temperature of the generator. A heat sink is usually composed of heat dissipation pipes, fins, and fans.

The working principle of a diesel generator radiator is to use coolant (usually water) to circulate in the heat dissipation pipe, transfer heat to the air through the heat dissipation fins, and exhaust the hot air through the fan. When a diesel generator is working, its engine will generate a large amount of heat. If it cannot dissipate heat in a timely manner, it will cause the generator to overheat and affect its normal operation. Therefore, the performance of the radiator directly affects the efficiency and reliability of the diesel generator. 

During the operation of a silent diesel generator set, the coolant in the heat dissipation tank is usually very hot and under high pressure. Therefore, it is strictly prohibited to tidy the radiator or remove pipes when not cooling, let alone operate or open the fan protective cover while the fan is rotating. 

Corrosion is the main cause of radiator failure. It is recommended to regularly check the pipeline joints to avoid leakage, and the water tank should be regularly filled with water to empty the air in the system. The cooling water tank should not be partially filled with water, as this usually accelerates the corrosion process. For non working generator sets, please evacuate or fill all water tanks. If conditions permit, use distilled water or natural soft water and add an appropriate amount of rust inhibitor.

Another issue is the cleanliness of the water tank. Water tank cleaning is divided into external cleaning and internal cleaning. This is an extremely important step that will directly affect the effectiveness of the radiator, thereby affecting the use of the entire silent diesel generator set. 

In outdoor working generator sets, the gap between the radiators may be blocked by debris, insects, and other debris. Low pressure hot water (with appropriate detergent added) can be sprayed frequently, paying attention to spraying steam or water from the front of the radiator to the fan. When spraying, cover the diesel engine and AC generator with a cloth. If the sediment is difficult to remove, remove the radiator and soak it in hot alkaline water for about 20 minutes, then rinse with hot water.

The silent diesel generator set needs to undergo regular maintenance and inspection. The operator conducting the inspection must master the safety operation instructions before starting the maintenance work.

Dingbo Power is a professional diesel generator manufacturer with 17 years of production experience. If you would like to learn more about diesel generators or would like to purchase diesel generators, please feel free to contact us via email dingbo@dieselgeneratortech.com .

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Connect A Diesel Generator to Your House?

Diesel generators are fuel-efficient and reliable, which can almost meet the power needs of any application. If you want to power the whole house during power shortages, it’s a good choice to choose a diesel generator set as the backup electricity supply. But how to connect a diesel generator to your house? Read on and you will find the answer. Options to connect a diesel generator to your home   Keep in mind that never plug your generator directly into the mains, or it will cause back feeding, damage your appliances and be life-threatening for utility workers. Generally, you can choose to connect a generator to your house by using extension cords or a transfer switch. Understanding the difference between them is helpful for you to choose the right type. Extension cords   Typically, extension cords are suitable for smaller diesel generators that used for short term. They require no installation and are cost-effective. If you need to power only some basic appliances such as...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...