Skip to main content

Key Knowledge Points of Shangchai Generator Set

Diesel generator sets are widely used in various fields such as industry, agricultural breeding, medical care, military, and schools. For users, it is becoming increasingly important to understand the knowledge and application of diesel generators. Today, the editor will share two pieces of knowledge with you. One is the usage instructions for generator sets at different altitudes and temperatures, and the other is the functions of the generator coupling.

The main components of a diesel generator set are the engine and the generator. Normally, we need an excellent diesel generator set to meet our power needs. Under different environmental temperatures and high - altitude conditions, what is the correct way to use it? The editor has summarized the following points for you:

Environmental temperature and altitude

The engine can operate under the following conditions without power adjustment:

For an engine with a rotational speed of 1800 r/min, the altitude is below 1525 m (5000 ft) and the environmental temperature is below 40°C (104°F).

For an engine with a rotational speed of 1500 r/min, the altitude is below 1525 m (5000 ft) and the environmental temperature is below 40°C (104°F).

When the generator operates beyond the above - mentioned conditions:

When the altitude is higher than 1525 m (5000 ft), for every 300 m (1000 ft) increase in altitude, the power should be reduced by 4%.

When the environmental temperature is higher than 40°C (104°F), for every 11°C increase in temperature, the power should be reduced by 2% (for every 10°F increase, the power should be reduced by 1%).

The above are the usage instructions for the Shangchai generator set at different altitudes and environmental temperatures, provided for your reference.

What are the functions of the generator coupling?

1.Connection device: The coupling is a connecting device used to connect power - output mechanisms such as engines and driven mechanisms. It connects working components on different working planes so that they can work together.

2.Power transmission component: When two different mechanisms are connected by a coupling, the driving mechanism drives the driven mechanism to work under the fixation of the coupling, transmitting torque and power. Some couplings can not only transmit torque and power but also have different degrees of axial, radial, and angular compensation capabilities.

3.Shock - absorption and buffering: The coupling has the functions of shock - absorption and buffering.

The functions of the coupling are roughly the above three types. According to their functions, couplings can be roughly divided into three categories: rigid couplings, flexible couplings, and safety couplings. Rigid couplings can only transmit motion and torque. Flexible couplings can not only transmit motion and torque but also have different degrees of axial, radial, and angular compensation capabilities, as well as different degrees of shock - absorption and buffering functions. Safety couplings transmit motion and torque and provide overload safety protection. Although the coupling is small, it is of great significance to a generator set. Therefore, we also need to pay attention to it and understand it better so that we can handle fault problems calmly. 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...