Skip to main content

Knowledge of The Turbocharged Iintercooler System of Shangchai Generators

In the turbo - charged and inter - cooled system of a diesel generator, when the air is compressed during the turbo - charging process, its temperature and pressure increase simultaneously. Without inter - cooling, the intake air density is limited by the adiabatic efficiency of the compressor. When the diesel engine is highly turbo - charged with a large pressure ratio, the inter - cooling technology can be used to increase the intake air density. Therefore, being familiar with the knowledge of the turbo - charged and inter - cooled system, which is a basic component of the Shangchai generator, is crucial for the later use, maintenance, and upkeep of the generator set. The editor of Dingbo Power will share relevant professional knowledge about the turbo - charged and inter - cooled system of the generator set to help everyone use the diesel generator more easily.

Composition of the exhaust system of YC12VC series generator diesel engines

The exhaust system of YC12VC series generator diesel engines is mainly composed of the following components: left and right intake and exhaust pipes, left and right turbochargers, left and right inter - coolers, and related pipelines.

 

Working principle of the turbo - charged and inter - cooled system

All YC12VC series generator diesel engines are equipped with an independent turbo - charged and inter - cooled system. When the engine is working, the exhaust gas from the engine exhaust pipe enters the turbine. The thermal energy of the exhaust gas makes the turbine rotate, which in turn drives the compressor connected to the turbine. The compressor sucks in and compresses the air, and then the compressed air enters the engine intake pipe through the pipeline. The cooled and expanded exhaust gas leaving the turbine is guided from the turbine housing to the engine exhaust system and then released into the atmosphere.

 

Advantages of turbo - charging and inter - cooling

After the intake air is compressed, the density of the air charged into the cylinder increases. With the good cooperation of the fuel supply system, more fuel can be fully burned, which improves the power and enhances the fuel economy. Turbo - charging and inter - cooling further cool the compressed air, increasing the air density and the intake air volume, thereby further improving the power and reducing the temperature in the combustion chamber.

 

Turbocharger

The turbocharger is a high - speed and precision machine and should not be disassembled casually. If it malfunctions, it should be sent to a maintenance center for repair. The two turbochargers are identical, and they can be adjusted by changing the rotation angle.

 

Precautions for use

1.Keep the engine idling before the lubricating oil pressure is established: Before the lubricating oil pressure of the engine is established, keep the engine at an idle state.

2.Gradually reduce the temperature and speed before engine shutdown: Before shutting down the engine, let its temperature and speed gradually decrease from the maximum values.

3.Pre - lubricate the turbocharger: After changing the lubricating oil or performing any maintenance (including draining the lubricating oil), the turbocharger needs to be pre - lubricated. Crank the crankshaft several times before starting the engine. After starting the engine, let it idle for a while to establish the entire lubricating oil circulation pressure before entering high - speed operation.

4.Be cautious when starting the engine at low temperatures: When the ambient temperature is too low or the engine is restarted after a long - term shutdown, it will affect the normal establishment of the engine lubricating oil flow and oil pressure. In this case, let the engine idle for a few minutes after starting, and only enter the normal working state after the oil pressure is normal.

5.Avoid long - term idling of the engine: The idling time generally should not exceed 5 minutes.

 

Inter - cooler

The generator diesel engine is equipped with a water - tank inter - cooler component. The air from the turbocharger compressor does not directly enter the engine intake pipe. Instead, the turbo - charged air is led to the inter - cooler through a pipe for water - air cooling. Here, the compressed air is cooled, further increasing its density, which is beneficial for improving the engine power and performance. The two inter - coolers used in this machine are the same.

 

As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...