What May Cause High Coolant Temperature of A Diesel Generator?

Diesel generators are an essential backup power source and they can provide reliable power for extended periods. When using a diesel generator set, you need to pay attention to the cooling water temperature. If the coolant temperature is too high, it may cause problems such as stuck piston, cylinder scoring, decreased engine oil viscosity and reduced generator performance. What may cause the excessively high water temperature of diesel generator?

Reasons for excessively high water temperature of diesel generator set

Clogged radiator

If the surface of radiator is mixed with engine oil, a sludge mixture of oil and dust can block the radiator and result in difficult to dissipate heat.

Improper use of coolant

Coolant is an important cooling material to reduce the genset temperature and water temperature of the unit. Faulty coolant or a lack thereof will seriously affect the cooling performance and even lead to a rapid rise in temperature. The engine will overheat.

Cooling water pump failure

When the cooling pump fails, it will lead to a small flow of coolant, which greatly reduces the cooling effect. Meanwhile, if there are many scale deposits in the pump, it will also reduce the heat dissipation performance.

Generator overloading

When a diesel generator set is overloaded, the oil supply will increase. This will further increase the heat of the whole machine and exceed the heat dissipation capacity of the unit. It may also lead to black smoke, loud noise and other problems.

Faulty thermostat

A thermostat in the cooling system of diesel generator is essentially a temperature regulator. When the thermostat is opened at about 85 degrees Celsius, it means that the thermostat is in good working condition. It will be fully opened at 105 degrees Celsius and operated at maximum coolant flow. More hot coolant will passe through the radiator, which lowers its temperature by transferring heat to the air. If the thermostat is defective, the high coolant temperature problem may occur.

How to fix the tool high coolant temperature problem for diesel generators?

Check the radiator and the pump

Radiator blockage and scale deposit in the pump are common reasons for too high coolant temperature in diesel generator. Check if the radiator fins are flattened or blocked. If they are flattened, you can use a thin steel sheet to carefully lift the fallen radiator fins back into place and restore their flat shape.‌ If they are blocked, you can use compressed air or a water gun to clean them to restore their heat dissipation effect. If necessary, hot water can be used together with the cleaning solution.

Check if the fans work properly. If the fan belt is loose, adjust or replace it to ensure that the fans can work effectively. If the fan blade is out of shape, correct or replace it. At the same time, it’s also necessary to ensure the cleanliness of the surrounding working environment and regularly clean the scale inside the radiator and the pump.

Use coolant and oil properly

Follow the user manual and generator manufacturer’s recommendations and use the right and high quality coolant and oil. Check the coolant and oil levels and maintain the oil and coolant at the correct levels.

Check the water temperature sensor and water temperature gauge

A faulty gauge can’t activate the cooling system. You can use a surface thermometer to measure the temperature at the water temperature sensor to determine if the coolant temperature is actually too high. If the water temperature gauge indicates something wrong, it may be a false alarm from the sensor or faulty gauge that needs to be calibrated or replaced.

Check the thermostat

A faulty thermostat will fail to keep the correct operating temperature of the entire power generating system. You can try removing the thermostat and heating it in the water container, and then testing its working condition with the water temperature gauge. If the thermostat fails, it should be repaired or replaced.

Reduce the load gradually

If the diesel generator is overloaded, you should reduce the load so that the engine gradually returns to its normal operating temperature.

Contact professional generator maintenance personnel in time

If the above methods cannot solve the problem, you may need to check whether there is a fault inside the engine, such as cylinder gasket damage and improper valve clearance. It is recommended to contact professional maintenance personnel for inspection and maintenance.

At Dingbo Power, we offer a wide range of power generator solutions that reliably cater to the power needs of various commercial and industrial facilities. Our wide diesel generator sets includes Cummins, Perkins, Volvo, Deutz, Yuchai and other engine brands that boast superior quality, performance and reliability. Contact us today for any further information or assistance regarding to electric generating sets.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...