How to Maintain Diesel Generator Sets on Construction Sites Properly?

As critical backup power equipment on construction sites, diesel generators play a vital role in ensuring the stable and reliable operation of all site operations. Regular maintenance and upkeep of diesel generator sets are key to guaranteeing their performance and lifespan. This article will provide a detailed explanation of diesel generator maintenance practices for construction sites from the following aspects.

Basic Maintenance of Diesel Generator Sets

Regular Inspection and Cleaning

Regular visual inspections of diesel generators are essential. Make sure the exterior surface of your generator and the generator room remain clean and tidy. Trailer-mounted mobile generators are commonly used on construction sites. Generally, the regular inspection items of generator include, but are not limited to: checking the tire pressure of the trailer, checking the trailer body connection bolts for looseness, checking if the soundproof enclosure bolts are loose, and confirming that the exhaust, air intake, and ventilation systems are functioning smoothly. Additionally, it is necessary to regularly clean the exhaust and ventilation systems to ensure they remain unobstructed, preventing dust and debris from affecting the equipment's heat dissipation and performance.

Fuel Management

Ensure the diesel fuel tank has an adequate fuel supply, typically enough to meet at least 8-12 hours of operation. Inspect the fuel system for leaks and replace the diesel fuel filters regularly to maintain fuel cleanliness. Using low-quality or contaminated fuel can clog filters and injectors, leading to reduced engine performance and increased maintenance costs. Therefore, it is essential to choose a reputable fuel supplier to ensure fuel quality.

Oil and Oil Filter Replacement

Engine oil, often referred to as the lifeblood of the engine, has many functions such as lubrication, cooling, cleaning, and rust prevention. Over time, engine oil degrades and loses its effectiveness. Thus, it is crucial to replace the engine oil and oil filters regularly. Generally, follow the intervals recommended in the generator set's user manual or by the manufacturer. Additionally, check for oil leaks and ensure the oil filters are in good condition.

Cooling System Maintenance

The cooling system of diesel generator regulates the engine's operating temperature to prevent overheating. Regularly check the coolant levels. Ensure the coolant is sufficient and it has not deteriorated. Clean dust and debris from the radiator surface to maintain its optimal heat dissipation performance. Furthermore, replace the antifreeze periodically to prevent the equipment from freezing and cracking during winter.

Professional Maintenance of Diesel Generators

Lubrication System Maintenance

Proper lubrication is crucial for the smooth operation of the generator engine. Regularly inspect the tension of fan belts and charger belts, and adjust or replace them as necessary. Additionally, check that all bolts on the unit for looseness, especially the external main connection bolts. Inspect the lubrication system to ensure there are no oil leaks. Make sure the oil filters are in good condition.

Air Filter Replacement

Air filters are responsible for filtering the air entering the engine, preventing dust and debris from getting into the cylinders. Over time, the air filters of diesel generator can become clogged, which will reduce air intake efficiency and affect engine performance. Therefore, regularly inspect the air filters and it is recommended to replace them annually or as needed.

Electrical System Inspection

Diesel generator sets rely on batteries to start and control. Regularly check the battery terminals for signs of corrosion and clean them. Ensure the batteries are securely fastened and properly connected. Periodically test the battery voltage and replace the batteries as needed to avoid unexpected failures.

Safety Protection Device Inspection

Diesel generators are often equipped with various safety protection devices, such as overspeed protection and overload protection. Regularly inspect the performance of these devices to ensure they function correctly in emergencies. Additionally, conduct simulated tests of the safety protection devices and perform constant-load operation tests to verify their performance.

In addition to the maintenance tasks mentioned above, regular performance testing of the generator set is also important. When a generator set malfunctions, timely and accurate fault diagnosis is key to resolving the issue. If you encounter generator faults or abnormal situations that cannot be resolved, promptly contact the manufacturer or professional maintenance personnel for assistance.

The maintenance of diesel generators on construction sites is an important and complicated work. Follow the user manual and the recommendations of generator manufacturer to maintain your diesel generator. Feel free to contact us with any questions, concerns, or inquiries to learn more about the products & services we provide.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...