Skip to main content

How to Avoid Excessive Wear and Tear of A Cummins Diesel Generator?

As an efficient power equipment, Cummins generator sets will inevitably wear out, to a certain extent, after being used for a period of time. This is a normal phenomenon in the use of mechanical equipment. However, if there is abnormal equipment wear, you need to pay close attention to it. In this article, we will explore how to avoid excessive wear and tear of a Cummin diesel generator.

Generally, Cummins diesel generator set wear is affected by a variety of factors, such as the quality of fuel and oil, the speed and load of diesel engine, environmental conditions and operating conditions.

How to avoid excessive wear and tear of the main components of Cummins diesel generators?

In order to avoid excessive wear of your diesel generator, there are several aspects you should pay attention to:

Use high quality fuel and engine oil

A diesel generator set can sustain damage when exposed to poor-quality fuel. High quality fuel can maintain the superior performance, reliability and usability of your diesel engine over time. Higher quality fuel works better and also protects your equipment. If the diesel fuel you use contains sulfur or other impurities, it will produce acidic substances and other corrosive substances during combustion, accelerating the wear of the cylinders. At the same time, if the heavy fraction content in diesel is too high, it is easy to lead to the formation of carbon deposits during combustion, which leads to wear between the piston ring and the cylinder. In addition, the viscosity of diesel also affects the generation of gas mixture and the stability of fuel supply equipment. Proper and good quality fuel helps the engine to run smoothly and efficiently, reducing wear and tear.

The engine oil's key role is to lubricate moving parts, reduce friction, and help in heat dissipation. Viscosity rating and additives are two key considerations when choosing oil for your diesel engine. Viscosity refers to the thickness of the oil, and it's essential to choose an oil with the right viscosity rating for your engine. High quality oils have additives that do more than just lubricate; they help neutralize combustion acids, protect against corrosion, clean engine components, and reduce emissions. You should always check the engine or owner's manual and use the oil specified. The manual will tell you the type or grade and the right viscosity.

The operation of your diesel generator remains stable

Experimental results show that the degree of friction increases with the increase of diesel engine speed and load. Because when the load increases, the unit pressure of the friction surface increases, resulting in a worse thermal state. When the speed increases, the number of frictions per unit time will increase significantly. In the case of the same power, the wear caused by the increase of speed is more notable than the wear caused by the increase of load. However, if the speed is too low, it will not be able to maintain good liquid lubrication conditions, which will also lead to increased wear. Overloading the generator or running it at full load for long periods of time can also lead to excessive wear and tear. Running your engine at the right RPM is important to ensure your engine gets a good workout on a regular basis. Try to avoid overloading, abrupt acceleration and sudden deceleration. This helps reducing the wear and tear of the engine.

Ensure the diesel generator operates at a proper temperature

The ambient temperature has a certain influence on the wear of Cummins diesel generator sets. Under high temperature conditions, the engine is prone to overheating, and the viscosity of the lubricating oil decreases, which will accelerate the wear of various components. Under the low temperature conditions, the viscosity of the lubricating oil increases, making it difficult to start the diesel engine. The coolant can’t maintain the normal temperature during operation, resulting in the wear and corrosion of the components. In addition, diesel engines wear out seriously when started at low temperatures.

The working temperature of Cummins diesel generator set is one of the important factors that affect the wear and tear of the generator. Due to the structural limitations of the cooling system, changes in the working load and speed, and fluctuations in the ambient temperature, the working temperature of the diesel engine will change significantly during operating. Practice has shown that the diesel generator can work at its optimal performance when the cooling water temperature is between75 to 85 ° C and the lubricating oil temperature is between 75 to 95 ° C. Therefore, it’s necessary to ensure the genset operates at a proper temperature.

Maintain the generator regularly

Regular generator maintenance is crucial for its proper functioning. Dirt and debris can clog the air filters, causing the engine to run inefficiently and leading to premature wear and tear. Regularly remove any dirt, dust, or debris that may accumulate on the generator's exterior. You need to regularly change oil and filters, maintain coolant levels, and ensure that all moving parts are in good condition. Recommended professional service frequencies for a diesel generator will depend on its usage and run time.

Dingbo Power is a professional diesel generator manufacturer with more than 17 year's production experience. We maintain close partnerships with upstream partners such as Cummins, Perkins, Deutz, Doosan, Volvo, Yuchai, Shangchai, Weichai, Stamford, Leroy Somer and others. Our products are high quality and affordable, which can meet your specific requirements. Feel free to contact us with any questions, concerns, or inquiries to learn more about the products & services we provide.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...