Skip to main content

Several Key Design Considerations for Containerized Diesel Generator Sets

With the improvement of social productivity and rapid economic growth, the demand for electricity is also increasing rapidly. Containerized diesel generator sets have emerged in recent years as a type of mobile power supply device, offering advantages such as easy mobility, good resistance to rain and dust, and relatively low noise. Below, we will explore several key factors to consider when designing a containerized diesel generator.

Compared to indoor-installed diesel generator sets, containerized generator sets have clear advantages in terms of project timelines: the approval process is relatively simplified, installation and commissioning cycles are shorter, and the reduced delivery time means faster capital recovery. The advantages of indoor installation include easier transportation of the unit, more space for maintenance, and a relatively smaller overall impact on the environment.

Regarding the key factors to consider when designing containerized generators in China today, we will elaborate on the following four points.

  1. Power output and cable selection

As a power supply device, containerised diesel generators’ power output, types of cables and the wiring method should be considered. In addition to the diesel genset, the container also houses other low-voltage auxiliary equipment. Designers should clearly define the types of these devices and their power requirements before starting the design process. It is essential to reserve capacity and power interfaces for the mains supply in advance, as well as control cable connections.

  1. Ventilation and heat dissipation

Generally, to reduce overall container noise levels and provide better protection, the noise-reducing enclosure is designed to be larger, which reduces airflow permeability. This can negatively impact the ventilation and heat dissipation of the entire unit. Therefore, when designing a container diesel generator, it is crucial to accurately calculate the intake and exhaust air resistance of the entire container to avoid exceeding the cooling system limits of the diesel generator set.

  1. Day tank capacity

Typically, a day tank is installed inside the container. Unlike indoor-installed diesel generating sets, which are often limited to a 1m³ day tank, the day tank capacity for containerized diesel generators can be slightly larger.

  1. Protection measures

Special attention should be paid to protective considerations for containerized diesel generator sets. In southern regions, the focus is on rainproofing, while in northern areas, additional measures such as protection against willow catkins, snow, cold, and insulation are necessary. For the fire protection system, a heptafluoropropane fire suppression system is commonly used inside the container. The fire protection system is often interconnected with the fuel supply system—when a fire alarm is triggered, it immediately issues an alert and rapidly discharges fuel from the day tank to prevent the fire from spreading further.

Consider diesel generators from Dingbo Power

At Dingbo Power, we provide different types of 100% brand new diesel generators, such as open-type, silent type, containerized type, trailer-mounted type, etc. Each type of generator sets have their advantages and disadvantages. You need to choose the right one based on your specific needs. Our containerized generators are packaged in ISO containers and the containerized line comes standard on a Department of Transportation (DoT) approved chassis.

For more information on container diesel generators or other power generators, reach out to us today.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...