Skip to main content

Impact of Plateau Environment on Diesel Generator Sets

China has a vast territory, and there are many high - altitude areas in the central and western regions, including Tibet, Qinghai, Yunnan, Guizhou, Sichuan and other places. In the remote areas of these provinces and autonomous regions, it is often difficult for the power supply to reach the load center. Therefore, diesel generator sets need to be purchased as the common power source.

In the plateau area, due to the high altitude, the oxygen in the air is relatively thin. People living on the plain usually have altitude sickness when they go there, which is generally manifested as mild headache, insomnia, mild chest tightness, excessive excitement, etc. The working principle of a diesel generator set is to obtain energy through the combustion of diesel. So, will the plateau environment have an impact on the use of diesel generator sets?

Due to the low air pressure and thin air in the plateau area, the oxygen content in the diesel generator set is low, and the ambient temperature of the diesel generator set is low. The diesel generator set has poor combustion due to insufficient intake air, so the diesel generator cannot output the originally specified rated power.

Different models of diesel generator sets have different working capabilities on the plateau. When a generator set is used on the plateau, for every 1000 - meter increase in altitude, the power of a non - turbocharged engine decreases by about 6 - 10%, and that of a turbocharged engine decreases by about 2 - 5%. Therefore, when a diesel generator set is used on the plateau for a long time, the fuel supply should be appropriately reduced according to the local altitude.

Considering the tendency of ignition delay under plateau conditions, for the operating economy of the diesel engine, it is generally recommended that the fuel supply advance angle of a naturally aspirated diesel engine should be appropriately advanced.

Experiments in recent years have proved that for diesel engines used in plateau areas, the method of exhaust gas turbocharging can be used for power compensation on the plateau. Through exhaust gas turbocharging, not only the lack of power on the plateau can be compensated, but also the smoke color can be improved, the power performance can be restored, and the fuel consumption rate can be reduced.

As the altitude increases, the ambient temperature is also lower than that in the plain area. Generally, for every 1000 - meter increase in altitude, the ambient temperature drops by about 0.6 degrees Celsius. In addition, due to the thin air on the plateau, according to Dingbo Power, a generator manufacturer, the starting performance of the diesel engine is worse than that in the plain area. Users should adopt corresponding auxiliary starting methods for low - temperature starting during use.

As the altitude increases, the boiling point of water decreases. At the same time, the air pressure and mass of the cooling air decrease, and the heat dissipation per kilowatt per unit time increases. Therefore, the heat - dissipation conditions of the cooling system are worse than those in the plain. Generally, the open - type cooling cycle is not suitable for high - altitude areas. A pressurized closed - type cooling system can be used to increase the boiling point of the coolant when used on the plateau.

Considering the tendency of ignition delay under plateau conditions, in order to improve the operating economy of the diesel generator, it is generally recommended that the fuel supply advance angle of a non - turbocharged diesel engine should be appropriately advanced.

Considering the above factors, when purchasing a diesel generator set, the user should inform the manufacturer of the operating environment of the unit and select a diesel generator set that can withstand harsh climate conditions and is suitable for the plateau. The diesel generator sets of Guangxi Dingbo Power can withstand the environmental tests on the plateau.

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...