The Relationship Between Diesel Engine Parameters

The three most commonly encountered data when understanding engine parameters are power, torque, and speed. You may have seen these terms and parameters in the manual, but you are not very familiar with their meanings. Today, Guangxi Dingbo Electric Power will discuss the relationship between these three factors with everyone. After understanding them, we can analyze the performance of the engine more comprehensively.

Firstly, Dingbo Power will introduce the concepts of these three, Engine Power unit: hp or kW; Engine Speed Unit: rpm; Torque unit: N·m; Power=n x torque x speed. What do power and torque represent? Why are diesel generators with higher engine power and torque more expensive? What is the relationship between power, speed, and torque? Why does a powerful engine depend on its power and torque? These four questions will be discussed and answered one by one below.

Torque is the force exerted by the piston during one cycle of an internal combustion engine to rotate the engine. There are generally two units of torque, the first being Newton meters; The second type is pound feet. In China, we generally use Newton meters (N · m) more frequently. How should Newton meters be understood? For example, if an engine bursts 200 Newton meters, it is equivalent to applying about 20 kilograms of weight on one end of a one meter lever.

RPM is the number of times the engine rotates in one minute, but there is a two-fold relationship between RPM and cycle. Because the widely used four stroke engine completes one power cycle every two revolutions. That is to say, the engine speed is at 8000 revolutions per minute, which is equivalent to only 4000 power cycles.

The physical definition of power is the amount of work done per unit time. Therefore, power is a physical quantity that describes the speed at which work is done. It can be understood as the energy generated by the engine per unit time. The greater the engine power, the faster the work is done, and the more energy is generated in the same amount of time. Normally, the higher the power of the engine, the higher its maximum speed.

The speed of a diesel engine is much lower than that of a gasoline engine, so under the same displacement, the power of a gasoline engine is higher than that of a diesel engine, but the torque of a diesel engine is higher than that of a gasoline engine. The main reason is that the combustion characteristics of fuels are different. Diesel has a slower combustion speed compared to gasoline, and it takes longer to release energy, resulting in a slower work rate and lower power output. Therefore, diesel engines generally adopt designs with small cylinder diameters and long strokes.

There is a proportional relationship between power, speed, and torque, where power=n x torque x speed (n is a constant). It is not difficult to understand why when we usually see the engine power curve, the torque will suddenly decrease when it reaches its peak, while the speed continues to increase the power and will continue to increase.

For example, the Shangchai E-series engine

1. Adopting turbocharging technology to increase intercooling and tap into the maximum power of the engine

2. The power coverage range is 360-460 horsepower, and the maximum torque can reach 2210 Newton meters

3. Maximum torque engine speed 1100-1400 revolutions per minute

4. Maximum power reserve coefficient 0.3

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...