Skip to main content

1500KW Cummins Marathon Containerized Silent Diesel Generator Set 3

Continuing from the previous text, this article continues to introduce the technical specifications and quotation of the 1500KW Cummins Shanghai Marathon containerized silent diesel generator set.

Diesel Engine Unit

·Diesel Engine Unit: Cummins brand KTA50-G15 engine, four-stroke, 12 cylinders, turbocharged, electronically regulated.

·Cooling Method: Water-cooled. The engine is equipped with a fan and a water tank for cooling.

·Diesel System: The Cummins KTA15-G15 the Cummins standard diesel system.

·Lubricating Oil Performance: It is recommended to refer to the standard lubricating oil configuration of the Cummins engine.

·Air Filter Element: Original Cummins air filter element

.Generator Part

·Generator: Marathon single-pivot brushless self-excited generator, motor model MX - 1540 - 4, main power of the motor is 1540KW / 1925KVA;

·Voltage: 230/400V; Frequency: 50Hz; Power factor: 0.8pf; Brushless (self-excited) excitation method.

·Motor: High-temperature insulation, energy-saving, and overload-resistant. The voltage and capacity of the DC system shall meet the requirements of the unit.

·Generator Protections: The generator shall have protective actions for generator short-circuit faults, generator overcurrent, generator grounding faults, generator loss of excitation, generator overvoltage, generator excitation circuit grounding, and other generator protections. In addition to the electrical protection requirements, the generator set control system has a number of typical alarm and shutdown functions.

·Generator Control System:

·Configure sufficient current transformers, relay protection systems, instrument measurements, etc. to ensure the safe and efficient operation of the diesel engine unit.

·The generator set control system, that is, the generator set control box, is arranged in the low-noise box of the low-noise generator for the convenience of operators to operate and monitor.

·The unit control system has main functions (not limited to these): Manual/automatic start and stop of the generator; Load control; Oil temperature and water temperature detection and alarm, etc. When the main power supply fails, the generator set can start automatically within 3 seconds; It can operate normally at full load (with all emergency loads) within 8 - 15 seconds. When the main power supply resumes normal, the generator set stops operating and returns to the emergency start state.

.Switchgear: The generator set is equipped with a switchgear for on-site protection. 3200A ABB 3P draw-out type circuit breaker.

The equipment is required to adopt the internationally renowned brand ABB with mature technology, which is suitable for this generator equipment.

4.2 Technical Regulations for Cummins Silent Generator Set

Please refer to the technical parameters of the generator set (Cummins KTA50-G15 engine paired with Marathon MP100-4 generator).

V. Tests

.All Cummins silent generator sets are subject to factory tests before leaving the factory. The buyer is welcome to visit the factory to observe the commissioning process. The tests can be completed under the supervision of the owner or a person authorized by the owner, and a test report will be issued.

.The on-site tests shall be organized by the owner, and the supplier shall provide necessary cooperation.

VI. Packaging and Transportation

6.1 Packaging

The generator set is delivered naked (with a container shell, no additional packaging is required). The supplier is responsible for transportation. The freight will be listed separately according to the delivery address provided by the owner and is not included in the price of the generator set. The owner is responsible for the loading and unloading of the unit at the place of use.

6.2 Transportation Requirements

.The transportation destination shall be designated by the owner. The product shall be firmly fixed and positioned during transportation.

.The safety and maintenance of the generator set during transportation shall be carried out in accordance with the transportation plan provided by the manufacturer. The transportation plan shall be provided to the owner for review and approval before transportation.

.The internal structure of the product shall remain in the same relative position and the fasteners shall not loosen after normal railway and road transportation.

.The product body, detachable components that can be assembled into a set, spare parts, and special tools shall not be lost, damaged, dampened, or corroded during transportation.

6.3 Loading and Unloading Requirements

The product body, detachable components that can be assembled into a set, and other shipped parts shall be equipped with lifting devices that can bear the overall weight.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...