Skip to main content

Shangchai Diesel Generator H Series Engine Part 2

This article continues to introduce the H series engines of Shangchai diesel generators.

Design features:

Referring to international first-class engine standards, using GPDP product development process, and collaborating with UK RICARDO to design according to the allowable burst pressure of 180 bar.

Design for vibration reduction and noise reduction, including rear gear chamber, high-strength alloy body, closed-loop frame structure, and main bearing diaphragm.

The size is 77-140mm shorter than similar products.

Progressiveness and reliability are guaranteed.

Low noise level of 3 decibels, comfortable driving experience.

Easy and flexible layout, good heat dissipation.

Reliability characteristics:

High strength frame structure, modular design, integrated oil cooler, water pump, and oil pump.

During the research and development phase, 20000 hours of bench reliability and durability tests were completed, as well as over 1 million kilometers of high-altitude, high-temperature, and cold road assessment tests.

The automated production and assembly line customized for the H series by international first-class equipment manufacturers such as HELLER, KUKA, USON, etc. is controlled by MES system.

Referring to the SPS system guarantee of German Volkswagen manufacturing standards, the product has good consistency and high reliability.

Reduce maintenance costs.

Good adaptability to high-altitude environments.

High attendance rate.

Matching adaptability:

4.3L and 6.5L displacement options are available, with diesel and natural gas engines available, covering a power range of 60-162kW.

Without an intake heating assist device, the cold start temperature is -15 ℃.

Match, optimize, and customize the engine and assembly based on the assembly configuration and actual operating conditions.

Multiple configurations of peripheral components such as flywheels, flywheel housings, generators, air compressors, and steering pumps are available for selection, PTO、 There are various structures and forms to choose from for the oil pan.

Diversified fuel options and wide power range.

Good environmental adaptability.

Simultaneous optimization of power and economy.

Meet various application requirements.

Maintenance and service:

The CAN bus layout can achieve intelligent real-time diagnosis.

The expansion type connecting rod has good accessibility for maintenance, and the electronic control system provides intelligent real-time diagnosis.

The average overhaul period exceeds 15000 hours, which is 50% longer than similar products.

Anti wear valve mechanism design, valve clearance adjustment time can be extended by 100%.

Convenient maintenance and high attendance rate.

The advanced design, powerful performance, high reliability, fuel efficiency, high attendance rate, and easy maintenance of the Shangchai H series engine are the reasons why it has gained recognition from customers and the market. Shangchai has been committed to creating high-quality products for many years, while bringing users a better user experience with reliable and efficient products.

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd is an early professional manufacturer of generators and diesel generator sets in China. The company has first-class national-level large-scale production and load testing equipment. Provide users with long-term diesel generator set sales, leasing, technical consultation, commissioning, maintenance, training services and generator set trusteeship business. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...