The mobile trailer generator set, also known as a mobile power station, is characterized by its mobility. It is highly needed in fields such as field engineering construction, emergency rescue, disaster relief, mining, military, and communication to improve the convenience of people's work in these areas. What issues should be noted when using a mobile trailer generator set? Diesel generator manufacturer Guangxi Dingbo Electric summarizes the following points, hoping to be helpful to users of mobile trailer generator sets.

After the mobile trailer generator set (mobile power station) is put into normal use, its operating status should be closely monitored. The indication values of all instruments should be frequently monitored and the overall operating status of the machine should be observed. The cooling system and some lubricating oil levels should be checked regularly. If any non-compliance or leakage is found, the cause should be immediately supplemented or checked to eliminate the fault of the mobile trailer generator set.

1. The working temperature of the mobile trailer generator set cannot be too low. When it is too low, the wear rate of the parts will accelerate, and the cylinder liner is also prone to cavitation. In addition, at low temperatures, lubricating oil has high viscosity and poor fluidity, which makes it difficult to enter the lubricating surface in a timely manner, and the fit between the piston and the cylinder is poor, making it easy to burn the engine oil. Therefore, it is generally stipulated that after the diesel generator set is started, the vehicle must be warmed up at a medium speed. The vehicle can only start driving when the water temperature reaches 40 ℃ or above, and can only operate with load after the water temperature reaches 60 ℃.

2. When using in winter, attention should be paid to antifreeze. After using the mobile trailer generator set, the cooling water should be drained to avoid freezing and damaging the body. Antifreeze can also be added to the cooling system to prevent the cooling water from freezing. If the temperature of the cooling water is too high before draining, the mobile trailer diesel generator set should be operated at low speed for a period of time, and the water should be drained after the temperature drops to avoid deformation or cracking of the cylinder head and cylinder block due to rapid temperature changes.

3. Pay attention to checking the tension of the fan belt. For diesel generator sets with natural convection cooling system, it is necessary to regularly check the tension of the fan belt during use. If the belt is too tight, it will accelerate the wear of the components and belt; The belt is too loose and the fan speed is not enough, which affects the cooling effect.

During the operation of the mobile trailer generator set, especially when the load is suddenly reduced, attention should be paid to preventing the diesel engine speed from suddenly increasing beyond the specified value due to the failure of the governor. Guangxi Dingbo Electric Power recommends that once such a situation occurs, emergency parking measures should be taken quickly, and then the cause should be identified and repaired.

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...