How to Effectively Solve the High Fuel Consumption in Volvo Diesel Generators

We all know that diesel generators are more fuel-efficient compared to gasoline generators, but after using them for a period of time, there will also be an increase in fuel consumption. As a commonly used  Volvo diesel generator, it also has this problem. So, what should we do if Volvo diesel generators consume more fuel? Today, Dingbo Power takes you to know how to effectively solve the problem of excessive fuel consumption in Volvo diesel generator sets.

 

The increase in fuel consumption of diesel generator sets is due to the following reasons:

1. The genset is worn out. Normal wear caused by long-term use of the engine, or abnormal wear caused by improper maintenance, can cause longitudinal pulling marks on the cylinder liner of the diesel engine. The cylinder diameter and piston side clearance exceed the specified values, resulting in a corresponding reduction in the support force of the piston rings and unclean oil scraping.

2. There is oil leakage at the connection. One of the main reasons for the excessive leakage of diesel generators is the oil leakage at the connections between the engine body and the gear compartment cover, as well as the large plate, rear cover, and cover on one side of the running wheel.

3. Worn valve guide


How to Effectively Solve the High Fuel Consumption in Volvo Diesel Generators


Solution to high fuel consumption of Volvo diesel generators:

1. Timely cleaning

(1) Regularly remove some minerals or impurities that have settled at the bottom of the fuel tank after use. If not cleaned regularly, it will affect the normal operation of the plunger and fuel injection head, causing inaccurate fuel supply time, uneven fuel supply, poor fuel atomization, and other phenomena, resulting in an increase in fuel volume.

 

(2) Timely remove carbon deposits. During the combustion process of a diesel engine, high temperatures are generated in the relevant components, resulting in the adhesion of ash carbon polymers to valves, valve seats, fuel injectors, piston tops, etc. Failure to clean them in a timely manner can increase fuel consumption and seriously affect the normal operation of the generator.

 

2. Correct use

(1) Maintain a certain water temperature during use. The cooling water temperature of the diesel engine is maintained at around 45-65 degrees. If the water temperature is too low, it will cause incomplete diesel combustion and increase the load capacity of the machine itself. Cooling water should not be abused with sewage, muddy water, or rainwater.

 

(2) Do not overload work. Overload operation causes a considerable portion of diesel fuel to turn into black smoke, which fails to exert its expected effective energy, increases fuel consumption, and also shortens the service life of related components.

 

(3) Purify the fuel before use. More than half of the faults of diesel generator sets come from the fuel supply system. The method of handling is to let the purchased diesel settle for 2-4 days before use, which can settle 98% of impurities. If you buy it now and use it now, you can place two layers of silk cloth or toilet paper at the fuel tank filler screen.

 

3. Ensure that the genset does not leak fuel.

(1) When excessive fuel consumption is found, it is necessary to first check whether there is fuel leakage at the connections between the engine body and the gear compartment cover, the large plate on one side of the driving wheel, the rear cover, and the cover. If there is an oil leak, attention should be paid to observing the integrity of the sealing gaskets at each connection part, and any damaged sealing gaskets should be replaced. If the sealing gasket is complete, check if the connecting screws of each part are loose. Use a wrench to tighten the loose bolts to the specified torque.  

 

(2) If the above parts are basically normal and the fuel leakage is located in the frame position, the fuel casing should be inspected. The main inspection area is at the front end of the fuel casing side on the same side as the driving wheel. Due to loose screws on the frame, the driving wheel has long-term friction with the frame angle iron that protects the fuel casing under the pulling of the triangular belt, which will grind the oil casing through and form a gap, resulting in fuel leakage.

 

We hope the above content is helpful to everyone. Dingbo Power is a manufacturer with 17 years of experience in producing diesel generators. If you are interested in diesel generator sets, please feel free to contact us via email dingbo@dieselgeneratortech.com .

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...