Skip to main content

What Are The Components of Diesel Generator Set?

 A diesel generator set is a power equipment that uses a diesel engine as power to drive an AC synchronous generator and generate electricity. Diesel generator sets are widely used power generation equipment in the world, mainly used as emergency backup power sources for telecommunications, finance, national defense, hospitals, schools, commercial, industrial and mining enterprises, and residential buildings; Independent power sources for special purposes such as mobile communication, battlefield and field operations, vehicles, and ships; The independent main power supply required for production and production in areas where the large power grid cannot deliver power or where it is not suitable to establish thermal power plants.


400 kva generator price


With the continuous development of science and technology and the application of new technologies and achievements, diesel generator sets are gradually moving from manual starting and manned ordinary units to automation (self starting unmanned, remote control, remote signaling, remote sensing), low emissions, and low noise directions to meet the higher requirements of modern society for diesel generator sets.

 

What are the components of a diesel generator set? A diesel generator set is a type of internal combustion generator set, consisting of a diesel engine, an AC synchronous generator, a control box (screen) coupling, and a common base.

 

Generally, the complete set of production units uses a common base to install the main components such as the diesel engine, AC synchronous generator, and control box (screen) into a whole, that is, an integrated diesel generator set. The high-power engine, diesel engine, and generator device need to be designed separately for equipment such as the support screen, fuel tank, and water tank outside the common base welded with steel sections, to facilitate movement and installation.

 

The flywheel housing of the diesel engine is directly connected to the front end cover of the generator through a shoulder positioning in the axial direction, and a cylindrical elastic coupling is used to drive the generator to rotate directly by the flywheel. This connection method is fixed together by screws, so that the two are connected as a whole, ensuring that the concentricity between the crankshaft of the diesel engine and the rotor of the generator is within the specified range.

 

In order to reduce noise, the unit generally needs to install a dedicated muffler. In special cases, the unit needs to be fully shielded. In order to reduce the vibration of the unit, shock absorbers or rubber alkali vibration pads are installed at the connection between the main components such as the diesel engine, generator, control box, and wooden box and the/k common bottom bear. Some control boxes also adopt secondary vibration reduction measures.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd is an early professional manufacturer of generators and diesel generator sets in China. The company has first-class national-level large-scale production and load testing equipment. Provide users with long-term diesel generator set sales, leasing, technical consultation, commissioning, maintenance, training services and generator set trusteeship business. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...