Skip to main content

Learn More About Diesel Power Generator Fuel Consumption

When investing in a power generator, you need to take some factors into consideration to find the right one that best fits your needs. Fuel efficiency should be one of the most primary considerations. A fuel efficient generator will offer significant fuel savings for you. Diesel generators are typically more efficient than gas-powered generators. In this article, you'll learn more about the fuel consumption of diesel power generators.

 

What is the fuel consumption of a diesel power generator?

Diesel generator sets can serve as backup emergency power in different scenarios and provide a stable and constant electricity during power outages. You have to have a basic understanding of fuel consumption of diesel generators in order to manage the operating costs.  

 

Diesel generators are known for their high thermal efficiency. A diesel power generator typically consists of a diesel engine and an electric generator. It usually runs on fuels such as diesel fuel and works by compressing air and burning fuel. Generally speaking, diesel engines have the highest thermal efficiency of any internal combustion engine. To practically describe the thermal efficiency, most manufacturers of diesel generators measure the consumption rate with G/KW.H (grams per kilowatt hour). Some manufacturers directly shows you the L/H (Liters Per Hour), which means how many liters of fuel are consumed in an hour.


Learn More About Diesel Power Generator Fuel Consumption

 

How many liters is a diesel generator per kwh? As a rule, a diesel generator requires 0.4 liters of fuel per kWh produced, which equates to a 25 percent efficiency ratio.

The following table shows an approximation of the diesel generator fuel consumption per hour in liters at different loading conditions:



Generator SizeApproximate Diesel Fuel Consumption

L/H at 50% loadL/H at 75% loadL/H at 100% load
8kW / 10kVA123
10kW / 12kVA234
12kW / 15kVA234
16kW / 20kVA345
20kW / 25kVA356
24kW / 30kVA457
32kW / 40kVA5810
40kW / 50kVA6912
60kW / 75kVA91419
80kW / 100kVA121825
120kW / 150kVA162432
200kW / 250kVA253850
640kW / 800kVA86129172
800kW / 1000kVA110170220
1000kW / 1250kVA130194259
1500kW / 1875kVA220295440
2000kW / 2500kVA275391550
2400kW / 3000kVA330467660


Friendly reminder: The figures in the chart should be used as an estimate only. Because they may change due to a variety of factors, such as the generator efficiency and the fuel condition.

 

The fuel consumption of diesel power generators are affected by a number of different factors, including their size, generator brands, power, and the loading condition, etc.  

 

How can you reduce the fuel consumption of your diesel power generator?

 

Due to the rising fuel costs and other factors, it's understandable that you want to reduce the fuel consumption for your diesel generator set. Blow are several recommendations to save fuel in the operation of a diesel generator:

 

1. Use the proper fuel

It’s important to use the fuel recommended by the manufacturer and avoid using fuel of poor quality, or the efficiency of your diesel power generator will be affected.

2. Use clean fuel

Additionally, using the fuel that contains impurities or sediment can reduce combustion and damage your generator. Keep in mind that always use clean fuel to improve the generator’s efficiency.

3. Keep the operating temperature of generator correct

Make sure the temperature of the cooling water reaches the correct standard. If the water temperature is incorrect, it will result in inefficient combustion of diesel fuel and the fuel consumption will increase eventually.

4. Select the right diesel generator

A high-quality with proper operation can greatly reduce fuel consumption. When buying a diesel generator, choose a generator brand which is fuel efficient and follow the manufacturer's instructions to operate the generator.

 

Read more about ways to reduce fuel consumption of diesel generator sets.

 

If you still have any questions about diesel power generator fuel consumption or are shopping for a new generator, contact us today! With years of experience, Dingbo Power can provide you with the right advice and help you choose a diesel generator that best meets your specific requirements.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...