Skip to main content

How to Choose Hospital Backup Diesel Generator Sets?

In today's society which is highly dependent on electricity, the healthcare industry has particularly stringent requirements for the stability and reliability of electricity. Hospitals are institutions providing medical and surgical treatment and nursing care for sick or injured people. The continuity of the power supply for hospitals is directly related to the life safety and treatment effect of patients. When the power goes out, patients and facility operations can suffer. Therefore, healthcare facilities such as hospitals can’t rely on the main power grid alone to provide their electricity. It’s essential for them to have backup generators that can ensure continuous operation even in the event of a power outage.

 

Hospital backup generators must power a large number of vital machinery, such as life support equipment and intravenous dispensing systems, to keep moving in case of an emergency. Regulatory agencies have imposed strict hospital backup generator requirements. There are two main types of generators used for hospitals: natural gas generators and diesel generators. Diesel generators are commonly used in healthcare facilities due to their reliability, durability and versatility. So how to choose hospital backup diesel generator sets?


How to Choose Hospital Backup Diesel Generator Sets?cid=56

 

Generator size and requirements

 

When selecting hospital backup diesel generator sets, the power needs for hospitals should be determined. This requires a detailed assessment and calculation of all critical loads in hospitals, including medical equipment in areas such as operating rooms, intensive care units, emergency rooms, and electricity requirements for infrastructure such as lighting and air conditioning. When choosing the generator output for hospital backup generators, select a rating that is approximately 20 to 25% higher than the peak load. A higher rated generator will operate comfortably at approximately 80% of its full capacity and will provide a margin of flexibility if the load increases in the future. Thus, it’s necessary to collaborate with facility management professionals to ensure alignment with a facility’s exact needs.

 

Fuel efficiency and reliability

 

Hospital backup diesel generator sets should have performance stability and reliability. The generator sets should maintain a stable output voltage and frequency when running for a long period of time during prolonged outages, ensuring the normal operation of medical equipment. At the same time, hospital backup generators should also have fuel economy and ability to operate with low noise in order to reduce operating costs and not affect the well-being of patients. In addition, the control systems of the generators should be advanced and reliable, with fault diagnosis and automatic protection functions to improve the overall reliability of the system.

 

Locations

 

Generally, to protect the generators from elements, most hospitals design or select a specific room for their generators. A generator room should have proper ventilation, lighting, insulation, fire protection and an efficient layout. Therefore, when choosing a location for these units, consider vibration impact, accessibility to trained staff, and good ventilation and sound mitigation. Make sure the generator rooms adhere to local building, fire, emissions and zoning codes.

 

Automatic switches for healthcare facilities

 

In the event of a power cut, hospital backup diesel generators should be quickly started and automatically switched to the emergency power supply mode to restore the power supply in the shortest time. A 10-second-or-less transfer time to ensure quick restoration of power is required. Therefore, each hospital generator should be equipped with an automatic transfer switch (ATS). With these switches, generators can kick in automatically when an outage from the main power grid is detected. Then, when the main power returns, these switches turn off the generators. In a hospital or healthcare facility, this switch is essential for meeting standards and protecting lives.

 

Intelligent management and remote monitoring system

 

The intelligent management and remote monitoring system, such as Dingbo Cloud service, is also important for hospital backup diesel generators. The platform has intelligent management capabilities, including remote monitoring, fault diagnosis, automatic load adjustment and other functions, which enable the operators to check the operating status and fault messages of the generator sets in real time, improving the operation efficiency and reliability of the backup generators. At the same time, the remote monitoring function can also help the operators to monitor and manage the generators remotely, reducing labor costs and improving work efficiency.

 

In summary

 

Diesel generators are an indispensable power support equipment for healthcare facilities. Choosing a right hospital backup diesel generator is essential. When selecting hospital generators, consider factors including generator size, performance stability, quick start capability, locations, intelligent management, brand and after-sales service, etc. Make sure the generators meet the actual needs of hospitals and protect the life safety of patients. With the continuous development of medical technology and the growing demand for electricity, healthcare facilities should also pay close attention to the latest developments and technical progress of the diesel generator industry in order to upgrade equipment in a timely manner and improve the level of power guarantee.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund