With the widespread use of diesel generator sets in various fields, their safety and security operations are also very important. Before timely maintenance or troubleshooting of diesel generator sets, maintenance personnel should carefully read and understand all safety precautions and warnings. The eight safety precautions for diesel generator sets are as follows:


emergency diesel generator


1、 The warning icon issued by the diesel generator set indicates potential danger that may cause personal injury or death, but as long as attention is paid and necessary measures are taken, the danger can be avoided. Dingbo Company reminds users that in order to ensure the safety of their surroundings, they should always consider potential dangers.

 

2、 Wear work clothes when operating, and never wear loose or damaged clothing.

 

3、 Be sure to wear protective goggles and shoes during operation.

 

4、 Do not pry the diesel engine to rotate at the fan area, as this abnormal operation can cause serious personal injury or damage to the fan blades.

 

5、 Before carrying out any maintenance work on diesel generators, the wiring of the battery should be removed first. If the air starter motor starts, the air connection pipe should be removed to prevent accidental starting. At the same time, a stop running sign should be hung in the operating room or control area.

 

6、 Before disassembling or releasing any pipes, fixed joints or related components, the pressure of the air, lubricating oil or coolant system should be released. Do not check for leaks by hand. High pressure fuel or lubricating oil can harm the human body.

 

7、 Preservatives contain strong alkalis, strictly preventing them from splashing into the eyes, let alone swallowing. If accidentally in contact with the skin, it should be washed promptly with soap or water.

 

8、 When the diesel generator set is in working condition or the coolant is in hot working condition, the diesel engine should be cooled first and then the water cover should be slowly opened to relieve the pressure of the cooling system.

 

Since 1982, Dingbo Generator has been a generator set manufacturer qualified by the "National Internal Combustion Engine Quality Supervision and Inspection Center". The product quality has passed the IS09001 quality system standard certification. And obtained the qualification certificate for self-operated import and export. Over the years, Dingbo units have been widely used in all walks of life, and have won the network access qualification of the Ministry of Information Industry, the network access qualification of the Ministry of Radio and Television, the network access qualification of CNPC, the network access qualification of China Mobile, and the manufacturing qualification of marine units. In 2016, Dingbo was awarded the Certificate of Qualified Supplier of China Nuclear Power Group. Dingbo Generator has been cooperating with Shangchai Power for many years. In 2009, it became the OEM partner of Shangchai Power in China. Dingbo generator VOLVO unit ranks the top three in the Asia-Pacific sales volume, and is the core OEM partner of Sweden Volvo in the Asia-Pacific region. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...