How to Select the Right Diesel Generator Battery?

Batteries are an important part of diesel generator sets. Though an electrical generator can provide a backup electricity supply when the grid fails, it requires a battery to provide enough start-up power to turn on. A defective battery can result in generator failure. Read on and you will understand the function of diesel generator battery and learn how to choose the right battery for your generator.

 

Why does a diesel generator need batteries?


The battery is one of the essential components of a diesel generator set. It’s mainly used to provide reliable starting power for diesel engine in the generator set. There are one or more starter motor(s) on the side of the diesel engine that require batteries to offer the juice to get the engine running. Usually, diesel gensets have more than one battery as the engines are large and heavy, which require a lot of energy to turn over.


How to Select the Right Diesel Generator Battery?cid=4

 

Depending on the design of the engine, the battery may have other functions:

Activate the glow plugs to start the generator.

Activate fuel shut-off value.

Power any electrical or digital control panel the generator may have.

Power to monitor the utility power or whether the fuel, engine oil, coolant and other conditions meet the starting requirements before starting.

Power ancillary panes and small motors that operate on DC current and any DC supplied device within the enclosure.

Power the secondary or redundant batteries or genset (if any).

Power for excitation (Some diesel generators require excitation after starting).

 

Types of battery used in diesel generator sets

 

The lead-acid batteries are commonly used in diesel generator set. The can also be used in cars and trucks. Lead-acid batteries are the oldest type of rechargeable battery and typically less expensive than other types of batteries. Diesel generator lead-acid batteries are mainly divided into two categories: dry-charged batteries and maintenance-free batteries.

 

Dry-charged batteries


The main feature of dry-charged battery is that its negative plate has a high storage capacity. It can save the obtained electricity in two years in a completely dry condition. When needed, just add the electrolyte and wait for 20-30 minutes, they will work. Dry-charged batteries have the advantages of stable voltage and low price. The advantages are low specific energy (electric energy stored per kilogram of battery), short lifespan and frequent routine maintenance.

 

Maintenance-free batteries


Due to its own structural advantages, the electrolyte of free-maintenance battery is consumed in a small amount, and there is little need to supplement distilled water during the service life. It also has the characteristics of shock resistance, high temperature resistance, compact size and low self-discharge. Its service life is generally twice that of ordinary batteries. There are two types of maintenance-free batteries on the market. One type is that the battery is added electrolyte all at once when purchased and no maintenance (adding supplementary liquid) is required in use. The other is that the battery itself has been filled with electrolyte and sealed when it leaves the factory. Users can’t add supplementary liquid to the battery. Read more about advantages of using maintenance free battery.

 

How do I choose a diesel generator battery?

 

Choosing the right battery is vital to the proper operation of diesel generator set. Diesel generator set lead-acid batteries are available in 2.4 V, 4 V, 6 V, 8 V, 12 V and 24 V series, with capacities ranging from 200 MAH to 3000 MAH. Usually, the battery used in a diesel generator is 12V DC battery or 24V DC battery. The size of the battery is dictated by generator size and what components the battery needs to power.

 

To choose the right diesel generator battery, there are a few factors you need to consider:

 

Check diesel generator manufacturer specifications for the battery recommendations and choose the correct size battery for the application.

Consider the ambient conditions like high temperature or low temperature and make sure the battery is suitable for the application.

Compare the currently installed battery against the manufacturer specifications. Installed batteries that exceed manufacturer’s specs are acceptable.

Review data from research to insure accuracy and purchase.

Ensure the availability of the battery in your area.

 

Generally, a well-maintained high quality diesel generator battery can last for 3-5 year, depending on use, charging setup and application.

 

Need advice on diesel generator batteries? Contact Dingbo Power!

 

If you are not sure which type of battery is right for your diesel generator set, contact us today. Dingbo Power is a professional diesel generator manufacturer with over 17 years’ experience and we can help you choose the best battery for your generator. We are an authorized OEM supplier of diesel engines for generator sets including Cummins, Perkins, Deutz, Yuchai, SDEC, MTU, Ricardo, Volvo, etc. Feel free to contact us with any questions, concerns, or inquiries to learn more about the products & services we provide.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...