Protection and fixation


perkins genset


During typhoon weather, protection and fixation are important measures to ensure the safety of diesel generator sets. It is necessary to regularly check whether the protective facilities of the equipment are intact, such as protective covers, nets, etc., to ensure that the equipment will not be eroded by wind and rain. At the same time, it is necessary to strengthen the fixation of equipment to ensure that it will not shake or collapse in strong wind weather.

 

During the installation process, a sufficient number and strength of fasteners should be used to securely mount the diesel generator set onto the bracket. At the same time, windproof barriers and other protective facilities should be installed around the equipment to reduce the impact of wind on the equipment.

 

Inspection and maintenance

 

It is crucial to strengthen the inspection and maintenance of diesel generator sets in extreme weather conditions. Regular inspections should be conducted on various performance indicators of the equipment, such as the fuel system, cooling system, electrical system, etc., to ensure that the equipment is in good working condition. At the same time, vulnerable parts and oil products should be replaced in a timely manner according to the usage of the equipment to ensure its normal operation.

 

Before extreme weather such as rainstorm and typhoon, the diesel generator set shall be comprehensively inspected and maintained in advance. Special attention should be paid to the waterproof, moisture-proof, protective, and fixed aspects of the equipment to ensure that it can operate normally in harsh weather conditions.

 

Emergency response and disposal

 

In extreme weather conditions, emergency response and disposal capabilities are the last line of defense to ensure the safe operation of diesel generator sets. A comprehensive emergency response mechanism should be established, and detailed emergency plans and disposal procedures should be formulated. Be able to respond quickly and take effective measures to handle equipment malfunctions or abnormal situations. In case of equipment malfunction or abnormal situation, the machine should be stopped immediately for inspection and professional personnel should be contacted for maintenance and handling.

 

In extreme weather conditions such as rainstorm and typhoon in summer, it is very important to use diesel generator set safely. By comprehensively applying measures such as site selection and installation, waterproofing and moisture-proof, protection and fixation, inspection and maintenance, and emergency response and disposal, it is possible to ensure the normal operation of diesel generator sets under adverse weather conditions and cope with various challenges.

 

Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f

Types of Diesel Engine and Application of Diesel Generator

This article will guide you to learn diesel engine types and important role of diesel generator. If you are interested, please keep reading.  What Are Diesel Engines? A type of internal combustion engine more accurately known as a compression ignition engine is designed to provide power by compressing the fuel at high temperature and significant pressure until it ignites. Diesel engines are either two-stroke or four-stroke .   ‘Stroke’ means the movement of the piston in the engine. Two-stroke This engine uses one stroke in each direction.   The first stroke being compression, which results in the ignition of the compressed fuel.   The return stroke brings new fuel into the cylinder. Four-stroke This engine has one compression stroke and one exhaust stroke and each one of those has a return stroke – hence, four-stroke. The compression stroke compresses the fuel/air mixture prior to ignition.   The exhaust stroke pushes the burnt gases out the exhaust. The