Diesel generators offer reliable power for homes and businesses. A well-maintained diesel generator can provide your uninterrupted power supply and peace of mind during critical situations. Bleeding the diesel engine is a part of the proper maintenance for a diesel generator. Read on and learn how to bleed air from your generator.

 

What does it mean to bleed a generator?

 

Bleeding a generator refers to removing any air that has entered your fuel system, which can help fix a number of issues and prevent worse problems from occurring. In general, air can enter your diesel engine’s fuel system when you run the generator dry without fuel or replace the fuel filter. Sometimes, repairs as well as leaks in your fuel lines can also lead to the problem. Air in the fuel system acts as a lock, preventing the normal supply of fuel into the cylinder. It can delay or prevent the diesel fuel from reaching the injectors, reducing the engine’s power and making your engine difficult to start or fail to start. Bleeding trapped air can quickly restore the flow of fuel into the engine and get your generator up and running again.

 

How do You Bleed Air from A Diesel Generator?cid=4

Do you have to bleed a diesel fuel system?

 

Yes. It’s essential to perform regular generator bleeding because air can sneakily enter your diesel generator, reducing engine performance and fuel economy, damaging critical engine parts over time and preventing your generator from starting entirely. Air entering the system is unavoidable in the daily operation of your diesel generator. Airlocks are air bubbles within a diesel fuel system, which usually occur due to filter changes, leaks or your engine running out of fuel. They can be addressed by bleeding. Bleeding the engine will improve fuel efficiency, reduce pollutants, and prevent engine damage. 

 

What are the symptoms of airlock in a diesel engine?

 

When air gets into your diesel system and airlocks occur, it will keep the diesel fuel from reaching the injectors and your engine’s performance can become compromised. A variety of engine performance problems will arise. The typical symptoms include harsh idling, sluggish acceleration, difficulty starting the engine, an obvious drop in power, strange noises coming from the engine,  black smoke, etc.  

 

How do you bleed air out of a diesel fuel system?

 

Identify the problem

 

When an airlock is likely to occur in your diesel fuel system’s engine, you need to find the source of the issue. In this way, you can prevent the air from re-entering the system after completing the bleeding process. Airlocks can happen when there is a small leak in your fuel system or when you change a diesel fuel filter, run out of fuel or disturb the fuel system. Thus, you need to check if there is any leak by a visual inspection of the generator. Pay attention to any signs like bubbles in the fuel or diesel fuel escaping the tank. If you recently changed the fuel filter, consider filling the new filter with oil and topping it off as it’s absorbed to close any gaps. Make sure you don’t leave your diesel generator to run dry.

 

Loosen the bleed screw

 

The bleed screw is a small valve in the fuel system of a diesel engine, which is designed to allow trapped air to exit the system and ensure that only pure fuel runs through the lines. You can find it near the fuel filter, close to the injector pump or at the high points of fuel lines. Loosen the screw or valve on the first filter a half turn at a time. Make sure not to take the entire screw out. Prepare a container or old rags for the next step, as the pressure from the air pockets might also release some fuel. 

 

Operate the manual fuel pump primer

 

The hand pump is in the engine compartment near the fuel filter or the injection pump. Use the manual pump to prime your diesel engine by pushing fuel through your system. As the air is pumped out of the generator system, you’ll notice bubbles beginning to form. Use rags to soak up the fuel that bubbles up, until the fuel that comes out is smooth and without bubbles. Repeat steps for the primary filter, fuel pump and injection lines if the engine doesn’t start or runs poorly.

 

It's worth noting that the actual procedure for bleeding a fuel system varies from engine manufacturer to engine manufacturer, Dingbo Power suggests that you follow the manufacturer’s instructions for any procedures that are specific to your model. If you are unfamiliar with this procedure, you can have it done by a professional.

 

Dingbo Power is a professional manufacturer of diesel generators. We offer a variety of gensets that can meet different needs. Feel free to contact us with any questions, concerns, or inquiries to learn more about the products & services we provide.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...