The high efficiency and energy-saving of diesel generators have made the diesel engine of automobiles increasingly apparent. The electronic fuel injection system is currently the main development feature of diesel engines and a powerful means to meet stricter emission regulations.


genset for sale


With the implementation of Euro III and IV emission standards, it is required to increase the pump end pressure of the distribution pump to over 100MPa. The original mechanical structure of the distribution pump can no longer meet the above requirements, and the mechanical structure of the distribution pump is facing new changes. A new type of VP44 internal cam electronic control distribution pump has been developed on the market. It adopts an internal cam, radial opposed plunger oil supply, and a distribution rotor rotating distribution structure. Using high-speed solenoid valves to directly control the high-pressure fuel supply. The pump end pressure is 100MPa, and by utilizing the pressure wave effect formed in the high-pressure oil pipe, the fuel injection pressure can reach 180MPa.


The fuel supply advance angle is controlled by a high-speed solenoid valve and can control the fuel supply rate and pre injection. At the same time, the hydraulic efficiency of this pump has reached a fully optimized level, and the power of the diesel generator equipped with this pump is much higher than that of the diesel engine equipped with a conventional distribution pump, but its peak driving torque is still at the same level.


The VP44 electronic distribution pump initially used three radial opposed plungers for oil supply, with a plunger diameter of 6.0mm and a cam lift of 3.5mm. Later, in order to increase the fuel injection pressure under partial load, it was improved to use two radially opposed plungers for fuel supply. The plunger diameter was increased to 7.0mm, and the cam lift was increased to 4.0mm. The maximum fuel supply for each cycle is 40-50mL, with a pre injection fuel volume between 1-3mL and an idle fuel injection volume of 4-5mL. The maximum fuel supply advance angle is 15 ° (oil pump shaft angle). It is generally suitable for diesel generators with 3, 4, 5, and 6 cylinders, a single cylinder displacement of less than 1L, and a maximum power of less than 250kw, and can meet the requirements of Euro III and Euro IV emission standards.


In order to further reduce emissions under partial loads, in addition to the measures taken by the oil pump, significant improvements have also been made to the fuel injectors: for the first time, a small pressure chamber type fuel injector and a dual directional needle valve have been adopted, greatly improving the formation of fuel jets, especially in the case of small fuel injection volume and needle valve lift under partial loads.


Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...