ATS Automatic Control Cabinet for Diesel Generators

Currently, more and more enterprises require the installation of automatic switch control cabinets when purchasing diesel generators. Why buy automatic control cabinets for diesel generators and automatic switches? Before discussing this issue, please follow Dingbo Power to understand the content of the automatic switch control cabinet.


diesel generator cost


ATS stands for Automatic Converter. The ATS control cabinet is mainly used in the automation system of the emergency power supply system, which automatically switches the load circuit from one power supply to another (backup) power supply to ensure the continuous and reliable operation of important loads. Therefore, ATS automatic control cabinets are often used as important places for electricity consumption, and the reliability of their products is particularly important. After a failed conversion, there are two dangers that arise:

 

The serious consequences are short circuits or power outages (even short circuits) on important loads. This situation not only causes economic losses (shutdown and financial paralysis), but also causes social problems (endangering life and safety). So, automatic control cabinets generally consist of switches and controllers. Switches are divided into computer level (integration level) and computer level (circuit breaker).

 

Computer proficiency: Single piece structure (three-point structure). This machine is a dedicated switch for dual power switching. The machine has a simple structure, small size, self-locking function, fast switching speed (within 0.2s), safety and reliability, but is equipped with a short circuit protection device.

 

CB level: ATS is equipped with overcurrent tripping, and the main contact can be connected to cut off short-circuit current. It consists of a circuit breaker and mechanical interlocking, and has the function of short circuit protection.

 

It mainly detects the working status of the monitored power supply (two circuits). If there is a power failure, such as phase loss, undervoltage, voltage loss, or frequency deviation, the controller will issue an action command and automatically switch from one power source to another. The capacity of a backup power supply is generally only 20% to 30% of that of a regular power supply.

 

At present, when users purchase diesel generator sets, they generally hope to install ATS automatic control cabinets. They think it's more convenient and doesn't require manual operation. However, there are now many types of ATS cabinets. One is a handmade ATS cabinet. The unit is a regular unit, and the ATS is a regular unit. When the mains power is stopped, the generator must be operated by hand. When the generator set is operating normally, manually press the switch button on the ATS panel. Although this method is quite cumbersome, the generator set and switchgear are not easily damaged. The second is the commonly used automatic switchgear. The unit adopts conventional automation. Simply add the electric throttle and electric switch to a regular coat. The switchgear is also a regular switchgear. This switch is relatively cheap, but has a high failure rate. So when choosing ATS, it is recommended to choose a fully automatic control cabinet. This type of ATS has an extremely low failure rate, and the prices of automatic diesel generator sets and automatic switchgear are generally high.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...