Skip to main content

Structural Requirements for Diesel Generator Sets 1

The structure of diesel generator sets includes: diesel engine system, fuel system, lubricating oil system, starting system, cooling system, intake system, heating system, noise and shock absorption system, etc. Do you know what are the requirements?

 

Fixed or mobile diesel generators should use high-performance equipment and cannot achieve the specified output power by increasing the speed. The diesel generator set should be modular and adopt fast self starting technology. The engine design, equipment, and control should comply with the specifications of heavy-duty fixed, continuous full/heavy load process application units, without any water, oil, or air leaks.

 

diesel generator container


The fuel consumption of diesel generator set under rated operating conditions shall not exceed 250G/(KWH), and the electricity consumption of generator set shall not exceed 4G/(KWH). The diesel generator set should be able to use domestically produced fuel and engine oil without affecting the output power and service life of the unit. The generator set manufacturer should provide the most suitable oil level and antifreeze measures for winter.

 

1. Diesel engine system

 

All rotating components of diesel generators should be equipped with spark free protection devices, and aluminum shell protection devices are not allowed.

 

Provide the steel structure base of the entire machine. The design of the sled should meet various load conditions, including testing, lifting, transportation, installation, and operation. Under any load condition, the deviation shall not exceed 1/400. Detailed foundation installation drawings shall be provided, necessary fixing bolts and damping equipment shall be provided to provide dynamic and static load torque, and internal connection lines and instrument lines, including flexible connection lines and devices from the fuel pump to the engine, shall be provided and installed. And provide exhaust pipes, soundproofing, expansion joints, chimneys, etc.

 

2. Fuel system

 

1) The daily fuel tank of the diesel generator set is allowed to be manually filled with oil at full load for 8 hours.

 

2) The daily fuel tank is equipped with on-site liquid level display and high and low liquid level switches. The output signal of the high and low liquid level switch should be coordinated with the gear oil pump and its motor control circuit provided by the buyer to achieve automatic oil injection.

 

3) The daily fuel tank should have at least an oil discharge port, air outlet, oil inlet, oil outlet, oil return port, and overflow port. All interfaces should be set on the side of the sled for easy connection and installation.

 

4) The elastic sleeve between the daily fuel tank and the supporting fuel pipeline of the unit, and the pipeline between the daily fuel tank and the generator (including pipe fittings, connectors, connectors, connectors, connectors, connectors, connectors, etc.), including valves and other accessories, should be within the scope of supply.

 

3. Lubricating oil system

 

1) The crankshaft connecting rod gear oil pump supplies oil to the main bearing, crankshaft pin shaft, piston, piston pin, and speed control gear. The cam bearing and valve rocker arm mechanism are under certain pressure.

 

2) The engine should have an appropriate lubricating oil cooler.

 

3) The lubricating oil filter should have a bypass for easy maintenance.

 

4) The lubricating oil tank should be equipped with oil injection holes and exhaust holes.

 

5) Set up a pre lubricating oil device. The pre lubrication oil pump is an electric continuous working type, interlocked with the startup control system to ensure sufficient lubrication during the initial startup.

 

6) Install a filter screen in front of the lubricating oil pump. Diesel generator manufacturers should provide the composition of lubricating oil for buyers to refer to when purchasing substitutes.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

How to Choose a Household Mini Generator

With the improvement of people's living standards, there are more and more household appliances, such as rice cookers, microwaves, kettles, refrigerators, air - conditioners, washing machines, etc. It can be said that every household has them. But what if there is a power outage? These appliances won't work properly, and our lives will be greatly disrupted. How can we avoid this? We can use household mini - generators to provide convenience in power consumption. So, how to choose a good household mini - generator? Consider the noise level Since it is for household use, when choosing a household mini - generator, we need to check whether the noise will affect the neighbors. Generally, the seller will demonstrate the performance of the generator in advance. A good household generator can reduce noise by about 80%. Choose a generator with a moderate price Due to different brands, there are significant differences in power, and consequently, the price differences of househ...

How to Choose Efficient Diesel Generators for the Film and Television Industry?

In the film and television industry, the stability of the electricity supply during filming is crucial. Whether the equipment are the cameras or the lighting equipment on the filming site, or the post-production equipment, they all need stable and reliable power support. Unstable or interrupted power can result in interrupted filming, damage to equipment, and even affecting the progress and quality of the entire project. Therefore, investing in high-efficiency diesel generator sets has become an important measure for the film and television industry to ensure the reliable power supply for shooting. Determine the power requirements Before choosing a diesel generator set for the film and television industry, it’s necessary to figure out the total power needs, including the electricity demand of the shooting location, the total power of the electrical equipment and the time of using electricity. Also consider whether there are special needs for the generators such as low noise level and...