Structural Requirements for Diesel Generator Sets 1

The structure of diesel generator sets includes: diesel engine system, fuel system, lubricating oil system, starting system, cooling system, intake system, heating system, noise and shock absorption system, etc. Do you know what are the requirements?

 

Fixed or mobile diesel generators should use high-performance equipment and cannot achieve the specified output power by increasing the speed. The diesel generator set should be modular and adopt fast self starting technology. The engine design, equipment, and control should comply with the specifications of heavy-duty fixed, continuous full/heavy load process application units, without any water, oil, or air leaks.

 

diesel generator container


The fuel consumption of diesel generator set under rated operating conditions shall not exceed 250G/(KWH), and the electricity consumption of generator set shall not exceed 4G/(KWH). The diesel generator set should be able to use domestically produced fuel and engine oil without affecting the output power and service life of the unit. The generator set manufacturer should provide the most suitable oil level and antifreeze measures for winter.

 

1. Diesel engine system

 

All rotating components of diesel generators should be equipped with spark free protection devices, and aluminum shell protection devices are not allowed.

 

Provide the steel structure base of the entire machine. The design of the sled should meet various load conditions, including testing, lifting, transportation, installation, and operation. Under any load condition, the deviation shall not exceed 1/400. Detailed foundation installation drawings shall be provided, necessary fixing bolts and damping equipment shall be provided to provide dynamic and static load torque, and internal connection lines and instrument lines, including flexible connection lines and devices from the fuel pump to the engine, shall be provided and installed. And provide exhaust pipes, soundproofing, expansion joints, chimneys, etc.

 

2. Fuel system

 

1) The daily fuel tank of the diesel generator set is allowed to be manually filled with oil at full load for 8 hours.

 

2) The daily fuel tank is equipped with on-site liquid level display and high and low liquid level switches. The output signal of the high and low liquid level switch should be coordinated with the gear oil pump and its motor control circuit provided by the buyer to achieve automatic oil injection.

 

3) The daily fuel tank should have at least an oil discharge port, air outlet, oil inlet, oil outlet, oil return port, and overflow port. All interfaces should be set on the side of the sled for easy connection and installation.

 

4) The elastic sleeve between the daily fuel tank and the supporting fuel pipeline of the unit, and the pipeline between the daily fuel tank and the generator (including pipe fittings, connectors, connectors, connectors, connectors, connectors, connectors, etc.), including valves and other accessories, should be within the scope of supply.

 

3. Lubricating oil system

 

1) The crankshaft connecting rod gear oil pump supplies oil to the main bearing, crankshaft pin shaft, piston, piston pin, and speed control gear. The cam bearing and valve rocker arm mechanism are under certain pressure.

 

2) The engine should have an appropriate lubricating oil cooler.

 

3) The lubricating oil filter should have a bypass for easy maintenance.

 

4) The lubricating oil tank should be equipped with oil injection holes and exhaust holes.

 

5) Set up a pre lubricating oil device. The pre lubrication oil pump is an electric continuous working type, interlocked with the startup control system to ensure sufficient lubrication during the initial startup.

 

6) Install a filter screen in front of the lubricating oil pump. Diesel generator manufacturers should provide the composition of lubricating oil for buyers to refer to when purchasing substitutes.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...