Skip to main content

Requirements for Nameplate of Diesel Generator Set

The requirements for materials, cleaning, and nameplates of diesel generators are as follows:

 

diesel generator dealers


Material requirements for diesel generators:

 

1. The performance of all materials should be suitable for the engineering and operational requirements of the project, and suitable for the conditions of operation, transportation, and installation locations. Maximize the use of materials that are serialized, standardized, and commercialized in the market.

 

2. Requirements for materials provided by third parties: The installation and use of equipment provided by third parties should be consistent with the supplier's instructions for the same type of equipment.

 

3. Consistency requirements for materials: Equipment and materials in the same supply contract should have the same type and functional structure, such as diodes, thyristors, switches, contactors, signal lights, operating mechanisms, auxiliary relays, instruments, etc.

 

Cleaning requirements for diesel generators:

 

1. The inside and outside of the generator set equipment must be clean.

 

2. All waste must be removed from each component, such as metal shavings or files, welding residues, dust, rags, fragments of debris, and other foreign objects. All scales, rust, oil stains, grease, powder or paint marks, and other harmful substances must be removed from the inner and outer surfaces of the diesel generator.

 

3. If necessary, solvent cleaning must be carried out in accordance with relevant regulations.

 

Diesel generator nameplate requirements:

 

1. Stainless steel or other corrosion-resistant metals should be used, with a rectangular shape. The background of the nameplate should be white and the text should be black. Warning signs should have a white background and red text. The text on the nameplate should be clearly visible from 1 meter of installation.

 

2. The nameplate should be fixed on the unit with stainless steel self tapping screws in a position that is easy to observe and cannot be moved, and adhesive should not be used.

 

3. Annotate content

 

4. Manufacturer's name, trademark, and order number

 

5. Model (including wiring scheme number), name, and factory serial number

 

6. Operating parameters (cylinder and stroke, rated power, rated frequency, rated voltage, rated current, number of phases, rated power factor, speed, ignition sequence)

 

7. Net weight, bottom plate weight, maximum detachable component weight of diesel generator

 

8. Protection level

 

9. Factory date

 

Founded in 1974, Dingbo Power Generation Equipment Co., Ltd. is a professional manufacturer of diesel engines, generators and generator sets, and one of the earliest manufacturers of diesel engines, generators and generator sets in China. Since 1992, the company has been a qualified generator set manufacturer inspected by the National Internal Combustion Engine Generator Set Quality Supervision and Inspection Center. Over the years, the company has carried out extensive cooperation with Shanghai Diesel, Weichai, Sweden Volvo, Sino US joint venture Chongqing Cummins, American Qianglu and other companies, and has become a (OEM) supporting factory and technical center. It has 64 sales service departments nationwide, providing users with design, supply, commissioning and maintenance services at any time. Dingbo quality is worth depending on. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Perkins Powerful 4000 Series Engine at Middle East Electricity

The Perkins team returns to Middle East Electricity (MEE) in 2017 to promote the full range of its diesel and gas electric power engines. Taking pride of place is the 4000 Series platform, which is designed to provide prime or standby power in critical applications. The evolution of the Perkins 4000 Series The steady evolution of the powerful 4000 Series has taken place over a number of years, thanks to significant investment from Perkins. Its development means the engine is used for prime and standby applications by original equipment manufacturers (OEMs) and end-users. The 4000 Series is tough and durable, provides consistent performance in the harshest conditions, and is proving to be a constant, reliable electric power source for prime applications all over the world. Perkins sells hundreds of 4000 Series engines every year into the prime power market. It has built more than 50,000 4000 Series engines for some of the world’s biggest businesses, and up to 30 pe...