Precautions for Low Load Operation of Diesel Generator Sets

 Long term full load operation of diesel generators can not only improve their performance, identify safety hazards, but also avoid major communication accidents. The relevant precautions include the following four aspects:


chinese diesel generator


Preparation before startup. Before turning on or off, be sure to check whether the cooling water or antifreeze in the diesel engine water tank meets the requirements, if it is not fully filled. Pull out the oil dipstick and check for any missing lubricating oil. If the specified "static" scale line is missing, carefully check the relevant parts for any potential faults. If any faults are found, promptly troubleshoot and start the machine.

 

It is strictly prohibited to start the diesel engine under load. Before starting a diesel engine, it should be noted that the output air switch of the generator must be in the closed state. After the ordinary diesel generator set is started, after 3-5 minutes of idling (about 700 rpm), the winter temperature is low, and the idling time should be appropriately extended for a few minutes. After starting a diesel engine, the first thing to observe is whether the oil pressure is normal and whether there are any abnormal phenomena such as oil or water leakage (under normal circumstances, the oil pressure is above 0.2MPa). If any abnormalities are found, the engine should be immediately shut down for maintenance. If there are no abnormal phenomena, increase the diesel engine speed to 1500 rpm. At this time, the generator displays a frequency of 50HZ and a voltage of 400V. Then, close the output air switch and put it into use. The unit shall not operate without load for a long time. (Due to prolonged no-load operation, the diesel engine's fuel injectors may spray diesel fuel and cause incomplete combustion, resulting in carbon deposits and valve and piston ring leaks.). If it is an automatic generator set, there is no need to run it at idle speed because the automatic generator set is generally equipped with a water heater, which keeps the diesel engine body at around 45Co. After starting, it can be powered normally within 8-15 seconds.

 

Pay attention to the working state during work. During the operation of the unit, a dedicated person should be on duty to regularly observe a series of faults, especially the changes in important factors such as engine oil pressure, water temperature, oil temperature, voltage, frequency, etc. In addition, it should be noted to have sufficient diesel fuel available. If fuel interruption occurs during operation, it may objectively cause a load shutdown, which may lead to damage to the generator excitation control system and related components.

 

Prohibit parking with load. Before each stop, gradually cut off the load, then turn off the output air switch of the unit, and finally let the diesel engine run at idle for about 3-5 minutes.

 

Therefore, Dingbo Company suggests that when using diesel generators, the operating time at low load/no load should be minimized as much as possible, and the minimum load should not be less than 25% -30% of the unit's rated power to prevent diesel generators from malfunctioning during low load operation. This is not only beneficial for extending the service life of diesel generators, but also for better performance.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...