Diesel Engine VE Distribution Pump Fuel Injection System

The diesel engine distribution pump fuel injection system is similar to the inline type in that it adopts a plunger type fuel injection pump and a mechanical centrifugal speed controller. The fuel injector is connected to the fuel injection pump through an oil pipe, and the fuel injector is a passive fuel injection system; The difference is that the distribution pump reduces the number of plunger pumps (only one plunger coupling), and high-pressure diesel is sent to the injectors of each cylinder in the working order of the distribution rotor. The high-pressure oil pipe must be connected according to the rotation direction of the distribution rotor and the working order of each cylinder during installation.


diesel engine


The reduction in the number of distribution pump plungers reduces the volume of the fuel injection pump itself, makes the structure more compact, reduces costs, and the increase in driving speed increases the fuel injection pressure.


The driving speed of the distribution pump can reach three times the crankshaft speed. On the premise that the sealing degree of the plunger coupling remains unchanged, the higher the driving speed of the fuel injection pump, the higher the fuel injection pressure, and the fuel injection pressure of the distribution pump can reach 60-80 MPa. High pressure injection is beneficial for diesel fuel to atomize combustion more fully and reduce smoke levels.


Cummins 6BT diesel generator, Iveco 8140 diesel generator, Isuzu 4JBI diesel generator, etc. all use a distribution pump fuel injection system, and an electronically controlled distribution pump fuel injection system has been developed.


Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd has been established for many years. In addition to strict requirements on the quality of diesel generator set products and after-sales service, it also has strict regulations on the plant environment, production equipment and supporting facilities, which reflects the strict style of Dingbo people. It is not only responsible for generator products, customers, but also employees, so that every employee of Dingbo Power generation equipment can work in a comfortable environment, Make it comfortable for every visiting customer to visit. Dingbo Power Group, relying on high-quality generators, generator sets, diesel generator, diesel generator sets, good services and the care of friends from all walks of life, carries forward the enterprise spirit of "pragmatic innovation, pioneering, unity and hard work, dare to be the first", and adheres to the enterprise style of "treating people with sincerity and heart to heart", has won the strong support of customers in the fields of post and telecommunications, finance, petrochemical, metallurgy, transportation, education, medical care, etc, Having a proud performance. Dingbo people are gradually moving towards economies of scale and entering the international market after joining the WTO with flexible sales strategies and relying on the company's advantages and strength. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

Factors to Consider When Choosing Diesel Generators for Data Centers

As the core facilities for data storage, processing and transmission, data centers’ stability and reliability are crucial in today's information age. Once the power supply interruption occurs, it can lead to data loss, business interruption, and even more serious consequences. Therefore, investing in one or more high-quality   diesel generators   for a data center is a key measure to ensure the continuity of power supply. Today, Dingbo Power will share several key factors that need to consider when purchasing data center diesel generator sets. Power requirements First of all, assess the power requirements of the data center based on the actual load conditions. This includes calculating the total power requirements of all critical equipment, as well as considering a possible increase in future needs. When selecting a diesel generator for the data center, make sure that the unit’s rated power can meet or exceed the peak load demand of the data center to ensure stable power suppl...