Today, we will briefly introduce the causes and solutions of the problem of engine oil (or oil-water mixture) spraying out from the generator oil pan. If you have any further information, please come to consult our Dingbo website. Next, we will introduce relevant information to everyone.

 

Excessive oil injection into the oil pan of the generator can also cause oil to come out of the oil dipstick. Pull out the oil dipstick to see if it exceeds the maximum mark by a large amount. If so, the excess part needs to be removed (special reminder: this inspection requires the generator to stop working for about 5 minutes).


power generator manufacturers


If the gap between the generator cylinder liner and piston is too large, a cylinder pressure test can be used to detect the cylinder compression ratio. If the compression ratio is low, the cylinder liner piston component (commonly known as the "four matching") should be replaced. If this problem is found after only replacing the piston ring during maintenance, it should be confirmed whether the piston ring is installed incorrectly. Usually, the ring ports of the three piston rings should be 120 degrees apart.


Check if the oil pan is filled with cooling water. When the cooling water leaks into the oil, the oil turns white and the capacity increases, causing oil to leak out of the oil dipstick. Pull out the oil dipstick to see if it exceeds the maximum mark by a lot. If so, follow the first step to troubleshoot.


The excessive clearance of the valve guide causes compressed air to pass through the guide to the rocker arm chamber (which is connected to the oil pan), generating high-pressure air, forcing the oil in the oil pan to emerge from the oil gauge port. If so, replace the valve guide.


If there is a turbocharger generator installed, if the turbocharger shaft and oil duct sealing ring are severely worn and damaged, causing high-pressure exhaust gas to enter the oil duct, forcing the oil in the oil pan out of the oil gauge port. If so, replace or repair the turbocharger.


Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Diesel Generator Power Ratings: Standby vs Prime vs Continuous

Diesel generator sets are commonly used in a variety of sectors due to their dependable performance and high efficiency. They can be used for emergency power supply in the event of a power cut or used in places without connection to a power grid. When selecting a diesel generator for your home or business, you need to consider many factors, such as generator’s ratings. In this article, we’ll explain the three basic rating types - standby, prime, and continuous in diesel generators. ISO-8528-1:2018 defines basic generator set rating categories based on four operational categories: Emergency Standby Power (ESP), Prime Power (PRP), Continuous Power (COP) and Limited-Time Running Prime (LTP). Read on and learn the application of power ratings for engines used in generating sets. Standby Power Rating Standby Power(ESP) is used to supply emergency power when the external power supply is interrupted, such as power outages. Standby power rated generators can supply reliable electricity as t...

Main Structural Features of Natural Gas Engine - Weichai WP13NG Gas Generator

1.1 Main structural features of natural gas engine ● A cover per cylinder, dependable operation, easy disassembly. ● Frame-type main bearing structure and high complete machine rigidity which benefits the reliability and  service life of complete machine. ● Electronic throttle is adopted to control engine revolving speed. ● Mixture supply system uses mixer to regulate air-fuel ratio and adopts proportional mix and supercharged inter-cooling method to stabilize gas supply. ● Water-cooling middle case turbocharger applicable to gas engine features is selected and circulating  water shall be used to cool down turbocharger lubrication cooling oil so as to effectively prevent  pressure bearing lubricating oil from coking and to improve turbocharger’s reliability. ● Designed gas mixing system satisfies gas fuel features to effectively support stable lean burn and enhance thermal efficiency. ● Two pairs of friction couples of inlet, outl...

What Should You Pay Attention to in Routine Maintenance of Diesel Generator Sets

In modern society, the stability of power supply is directly related to the operation efficiency of enterprises and people's quality of life. Diesel generators have become an indispensable backup power supply or main power source in various industries due to their high efficiency, durability and reliability. However, to ensure the smooth operation and optimal performance of the generator sets, regular maintenance is essential. Here is what you need to pay attention to in the routine maintenance of diesel generators. Keep your generator clean It’s important to keep the generator’s exterior and the generator room clean. Regularly remove any dirt, dust, or debris that may accumulate to on the generator’s surface. This is not only for the sake of beauty, but also for the smooth operation of the unit. Cleaning the generator’s exterior, air intake vents, exhaust outlets and generator room can effectively reduce the risk of generator overheating. In addition, check if the connection bol...