In the actual use of generator sets, there may be the phenomenon of fuel entering the oil pan. In order to prevent or minimize this phenomenon, this article will analyze the reasons for it for everyone


diesel generator manufacturers


1. Analysis of the PT fuel pump inlet of the generator set


The main function of the PT fuel pump is to add low pressure fuel (about 0.8~1.2MPa) and deliver it to the fuel injector. When the main shaft oil seal at the PT pump coupling fails, fuel will pass through this oil seal and enter the oil pan through the timing gearbox. At this point, the PT pump spindle oil seal must be replaced.


There is a dual purpose electromagnetic and manual shut-off valve at the outlet of the PT pump. When the ignition switch is turned on, the electromagnetic shut-off valve opens and the oil circuit is connected; When the ignition switch is turned off, the sealing ring of the shut-off valve is closed under the action of the spring plate, and the oil circuit is cut off. When the sealing ring of the shut-off valve fails or the diesel engine operates for a period of time, due to impurities in the diesel, the solenoid valve is not tightly closed. Fuel will also flow to the fuel injector through the shut-off valve and penetrate into the oil pan through the combustion chamber.


2. Analysis of fuel injection into the fuel injector of the generator set


The function of the fuel injector is to measure, pressurize (approximately 110-120MPa) the fuel output from the PT pump and inject it into the combustion chamber. When the nozzle hole of the fuel injector (normally about 0.2032mm) is too large or damaged, fuel will drip into the combustion chamber and seep into the oil pan during shutdown. At this point, it is necessary to dismantle and replace the abnormal fuel injector. If the upper and lower O-ring seals of the fuel injector fail, fuel will enter the valve chamber and combustion chamber through the seals at any time, and then penetrate into the oil pan.


3. Analysis of the fuel tank inlet of the generator set


The fuel tank of the PT fuel system is located at a higher position, and during shutdown, the fuel flows through the float tank and PT pump into the fuel injector, passes through the combustion chamber, and seeps into the oil pan. Moreover, due to the high position of the fuel tank, the return oil may not be smooth, especially when the return oil pressure decreases after shutdown. If the elevation of the fuel tank is too high, the return oil cannot return to the fuel tank and can only enter the combustion chamber and then enter the oil pan through the fuel injector.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...