Precautions for Generators During Maintenance or Repair

Today, we will briefly introduce the precautions for generators during maintenance or repair. If you have any further information, please feel free to consult our Dingbo website. Next, we will introduce relevant materials to you.


diesel engine generator


Unauthorized personnel are not allowed to approach the generator during maintenance or repair; The generator air circuit breaker should be in the OFF position, disconnect the power switch of the development motor control system, disconnect the "negative" pole line of the battery, and press the emergency stop button.


Do not turn on the machine when the fan protective cover or other safety protective cover is removed; Do not attempt to reach under or near these protective devices for maintenance while the generator is running. Keep palms, arms, long hair, jewelry, and loose clothing away from generator pulleys, belts, and other rotating parts. When working in the computer room, it is necessary to wear work clothes, gloves, hats, etc.


When the coolant is not completely cooled, it is prohibited to unscrew the radiator top cover to prevent steam (hot water) from spraying and injuring people. Do not swallow or touch liquids such as fuel, coolant, lubricants, electrolytes, etc; If the body accidentally comes into contact with the electrolyte, it should be immediately rinsed with a large amount of water. In severe cases, seek medical attention immediately.


When entering the generator operating room, it is necessary to wear protective equipment, especially earmuffs, to prevent damage to hearing. When connecting power output cables to the generator, qualified power cables must be used, and the connection process must comply with the relevant conditions, specifications, and standards for power distribution. When installing the generator, if welding is required, be sure to disconnect all electronic components inside the generator (such as controllers, electronic regulators, AVR, electronic injection machines, ECU, etc.); The grounding point should be as close as possible to the welding operation point to prevent damage to the internal electrical appliances, bearings, bearing shells, etc. of the generator caused by high welding current.


Since 1982, Dingbo Generator has been a generator set manufacturer qualified by the "National Internal Combustion Engine Quality Supervision and Inspection Center". The product quality has passed the IS09001 quality system standard certification. And obtained the qualification certificate for self-operated import and export. Over the years, Dingbo units have been widely used in all walks of life, and have won the network access qualification of the Ministry of Information Industry, the network access qualification of the Ministry of Radio and Television, the network access qualification of CNPC, the network access qualification of China Mobile, and the manufacturing qualification of marine units. In 2016, Dingbo was awarded the Certificate of Qualified Supplier of China Nuclear Power Group. Dingbo Generator has been cooperating with Shangchai Power for many years. In 2009, it became the OEM partner of Shangchai Power in China. Dingbo generator VOLVO unit ranks the top three in the Asia-Pacific sales volume, and is the core OEM partner of Sweden Volvo in the Asia-Pacific region. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

What Is the Difference Between Electric Motor and Electric Generator

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and winding currents to generate force. In certain applications, such as in regenerative braking with traction motors, electric motors can be used in reverse as generators to recover energy that might otherwise be lost as heat and friction. An electric generator operates in the reverse direction, converting mechanical energy into electrical energy. Electric generator can be divided into various type, open type, silent type, trailer type, portable type and container type, etc. Electric generator is mainly composed of diesel engine & alternator. Electric generator set is mainly composed of engine, alternator, control module, and common base. Electric generator :- Electric generator is a type of machine which converts mechanical input (energy) into electrical output (...

Engine Fault Code Messages - Volvo Penta Engine

Volvo Penta Engine Fault Code When a malfunction has occurred and the diagnostic system has generated one or more fault codes, these are read out differently depending on the equipment used. Please refer to “Fault code messages”. If the system indicates that a fault code has been set: 1 Cut engine speed to idle, or shut the Volvo engine off. 2 For DCU/DU Read the fault code from the display, please refer to Reading fault codes via the DCU or Reading fault codes via the DU. For CIU press the diagnostic button and read the fault code, by observing the flashing of the diagnostic lamp. Refer to Reading fault codes via the diagnostic lamp, CIU. 3 Look up the fault code in the Fault Code Register chapter and take the recommended measures. Reading fault codes via the DU (Display Unit) Depending on the severity of the fault the text, either WARNING! or ALARM STOP (a buzzer sounds) will be shown on the display 1 Press any button to come to the fault list. The f...

Yuchai 4D24 & 4D24T Series Diesel Engine Operation Guide

Yuchai 4D24 & 4D24T series off-highway diesel engines are developed by RAYWIN POWERTRAIN TECHNOLOGY CO., LTD. with international engine R&D institutions together. Adopted tunnel block, rotary fuel pump (mechanic or electric governor), turbocharged/naturally aspirated and 2-valve technologies, 4D24 series engines are with reliable, fuel-efficient and strong power characters. It could be applied for agriculture & garden fields, construction equipment, power generation , marine and industrial equipment. General Safety Rules Incorrect procedures, carelessness or neglect of warning instructions may cause burns, cuts, body mutilation, asphyxiation or other injury or even death. Before maintenance, please read and understand all the security measures instructions and warnings carefully. The following pages contain a general security measures to ensure personal safety that you should follow. ◆ Maintenance area should be dry, bright and well ventilation, no sund...